Desa LMFP33NR(B) Benutzerhandbuch

Seite von 36
www.desatech.com
119526-01A
24
pOSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned
wrong
7. Ignitor electrode broken
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when installed
5. Depleted gas supply (propane/
LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
3. Tighten nut holding piezo ig-
nitor to base panel of log set. Nut
is located behind base panel
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP gas
company
6. Clean ODS/pilot (see Cleaning 
and Maintenance, page 23) or
replace ODS/pilot assembly
7. Replace gas regulator
OBSERvED pROBLEM
When ignitor button is pressed,
there is no spark at ODS/pilot
When ignitor button is pressed,
there is spark at ODS/pilot but 
no ignition
TROUBLESHOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
All troubleshooting items are listed in order of operation.