Auto Shutoff Feature
1.  If the average room temperature exceeds 
82 degrees Fahrenheit (28 degrees Centi-
grade), the hand-held remote control will 
perform a safety override and shut the 
fireplace off. This feature is not available 
in the MANU mode.
2.  The receiver continuously receives signals 
from the hand-held remote to control the 
room temperature. If the hand-held remote 
is misplaced, obstructed or for any reason 
cannot transmit to the receiver, the receiver 
will shut off the fireplace after 8 minutes.
Key Pad Lock Feature
This feature allows the user to lock/unlock 
the keypad on the hand-held remote in the 
MANU or AUTO mode to prevent inadvertent 
operation (i.e. children operating the hand-held 
remote control, etc.). The keypad is locked in 
either on or off. Press the POWER and LOCK 
buttons together to turn the unit on or off.
OPTIONAL BLOWER 
OPERATION
Locate the blower switch by opening lower lou-
ver on fireplace insert. Blower switch is located 
at lower left inside louver door. 
This thermostat-controlled blower has three 
settings: ON, OFF and AUTO. In the ON posi-
tion, the blower will operate constantly. In the 
OFF position, the blower will not operate. In 
the AUTO position, the blower will start when 
the thermostat senses a sufficient increase in 
firebox temperature. 
Note:
 Your gas logs and thermostat blower 
will not turn on and off at the same time. The 
fireplace insert may run for several minutes 
before the blower turns on. After the heater 
modulates to the pilot position, the blower will 
continue to run. The blower will shut off after 
the firebox temperature decreases.
Note:
 It is safe to operate fireplace insert with 
blower turned off. However, the blower helps 
distribute heated air from the fireplace insert.
OpERATiNG FiREplAcE 
iNSERT
Continued
iNSpEcTiNG BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAME PATTERN
Figure 36 shows a correct pilot flame pattern. 
Figure 37 shows an incorrect pilot flame pattern. 
The incorrect pilot flame is not properly heating 
the thermocouple. When the thermocouple cools, 
the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 37
•  turn heater off (see To Turn Off Gas to Appli-
ance, page 20)
•  see Troubleshooting, page 25
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 36 - Correct Pilot Flame Pattern
Pilot Burner
Figure 37 - Incorrect Pilot Flame Pattern
Pilot Burner
Natural Gas
  
Pilot Burner Thermocouple
Pilot Burner
Thermocouple
Natural Gas
Propane/LP Gas
Propane/LP Gas