VENTING INSTALLATION 
INSTRUCTIONS
NOTICE: Read these instructions completely before 
attempting installation.
These models are tested and approved for use with DESA (direct-
vent) pipe components and terminations.
The venting system must terminate on the outside of the structure and 
can not be attached to a chimney or flue system serving a separate 
solid fuel or gas burning appliance. A direct-vent appliance must have 
its own venting system. DO NOT common vent this appliance.
These models are approved to be vented either horizontally through 
an outside wall or vertically through a roof or chase enclosure using 
the following guidelines:
•  When venting system terminates horizontally on an outside 
wall, you may install a standoff if the termination cap is to be 
installed directly on a combustible finish such as vinyl, wood, 
stucco, etc.
•  Never run the vent downward as this may cause excessive tem-
peratures which could cause a fire.
•  Vent pipe air space clearances to combustibles are 1" on all sides 
except on the horizontal sections, which requires 2" clearance 
from the top of the pipe. Where the termination cap penetrates 
a combustible wall, 1" air space clearance is required.
•  Snorkel terminations are required when minimum clearance to grade 
cannot be met (see Figure 16 on page 11).
•  Have fireplace and selected vent components on hand to help 
determine the exact measurements when elbowing or offsetting. 
Always use wall firestops when penetrating walls and firestops 
when penetrating ceilings or attic spaces.
•  Install horizontal venting with a 1/4" rise for every 12" of run 
toward the termination.
 WARNING: Read all instructions completely and 
thoroughly before attempting installation. Failure to 
do so could result in serious injury, property damage 
or loss of life.
IMPORTANT:
 Do not seal vent cap to pipe. Cap must be remov-
able for service.
NOTICE: Failure to follow these instructions will void 
the warranty.
INSTALLATION PRECAUTIONS
•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders or when on roof tops
•  Be aware of electrical wiring locations in walls and ceilings
The following actions will void the warranty on your venting 
system:
•  Installation of any damaged venting component
•  Unauthorized modification of the venting system (Do not cut 
or alter vent components)
•  Installation of any component part not manufactured or 
approved by DESA
•  Installation other than as instructed by these instructions
 WARNING: This gas fireplace and vent assembly 
must be vented directly to the outside. The venting 
system must NEVER be attached to a chimney serv-
ing  a  separate  solid  fuel  burning  appliance.  Each 
direct-vent gas appliance must use a separate vent 
system. Do not use common vent systems.
 WARNING: Vent pipe air space clearances to com-
bustibles are 1" on all sides except on the horizontal 
sections, which require 2" clearances from the top of 
the pipe. Where the termination cap penetrates a com-
bustible wall, 1" air space clearance is required.
VENTING INSTALLATION INSTRUCTIONS
Installation Precautions