Figure 2 - Typical Two-Sided Fireplace 
Installation 
INTRODUCTION
Models GL36PN/P and GL36PNE/P are decora-
tive gas appliances that use a millivolt gas control 
and piezo pilot or an electronic gas control valve 
with an electronic ignition system respectively. 
These systems require a 6", B-type venting system 
for operation.
The 6" B-type vent is not supplied by DESA. 
For  installation  guidelines,  check  your  B-vent 
instructions.
  WARNING:  This  gas  appli-
ance must not be connected to 
a chimney flue servicing a solid 
fuel burning appliance.
Models GL36PN and GL36PNE are smooth face 
units  for  natural  gas  only. The  GL36PNP  and 
GL36PNEP are smooth face units for propane/LP 
gas only. To determine which type of gas your unit 
is approved and tested for, check the rating plate on 
the lift-out plate located inside the firebox under 
the access panel.
BEFORE YOU BEGIN
Before beginning the installation of your appli-
ance, read these instructions through completely.
This DESA appliance and its approved compo-
nents are safe when installed according to this 
installation manual and are operated as recom-
mended by DESA. Unless you use DESA approved 
components tested for this appliance, YOU MAY 
CAUSE A FIRE HAZARD!
The DESA warranty will be voided by and DESA dis-
claims any responsibility for the following actions :
A)  Modification of the appliance or any of the 
components manufactured by DESA unless 
otherwise permitted by DESA.
B)  Use of any component part not approved by 
DESA in combination with this appliance.
C)  Installation and/or operation in a manner other 
than instructed in this manual.
D)  The burning of anything other than the type of 
gas approved for use in this gas appliance.
This appliance, when installed, must be electrically 
grounded in accordance with local codes or, in the 
absence of local codes, with the National Electri-
cal Code, ANSI/NFPA 70-1987 and the CSA C22.1 
Canadian Electrical Code for Canada.
The installation must conform with local codes 
or, in the absence of local codes, with the current 
National Fuel Gas Code, ANSI Z223.1/NFPA 54 
or with the current CAN/CGA B149 Installation 
Codes for Canada.
This appliance complies with ANSI Z21.50B-1990 
and CAM/CGA-2.22-M89 as a Vented Gas Ap-
pliance and is listed and tested by the Omni Test 
Laboratories.
  WARNING:  Installation  of 
this appliance should be done by 
a  qualified  service  person  well 
trained in the installation of such 
appliances. You  will  also  need  a 
building  permit  from  your  local 
Building and Safety Commissioner 
before  installing  this  appliance; 
otherwise your insurance compa-
ny may not cover this appliance.
NOTICE:  This  appliance  is  not 
intended to be used as a primary 
source of heat.
SELECTING LOCATION
To determine the safest and most efficient location 
for your appliance, you must take into consider-
ation the following guidelines:
1.  The location must allow for proper clearances 
(see Clearances, page 6). Note: This decora-
tive appliance is not designed for outdoor 
installation.
2.  The location should be in a place where drafts, 
air conditioning ducts, windows or doors will 
not affect fireplace heat output.
3.  A location that avoids the cutting of joists 
or roof rafters will make installation easier. 
Figure 2 shows a typical three-sided fireplace 
installation.
IMPORTANT:
 Side openings must be located at 
least 3 feet from facing wall or combustible mate-
rial. End opening must be located at least 1 foot 
from facing wall or combustible material.
Existing 
Side 
Wall
4" From Opening to 
Perpendicular Wall
Access 
Control Panel