Figure 8 - Lineal Gain
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
36"
Fireplace
37
1
/
"
12-8DM
1-8HT
Pipe Section
10
5
/
8
"
18-8DM
18-8HT
Pipe Section
16
5
/
8
"
24-8DM
4-8HT
Pipe Section
3
5
/
8
"
36-8DM
36-8HT
Pipe Section
34
5
/
8
"
48-8DM
48-8HT
Pipe Section
46
5
/
8
"
RT-8DM
RT-8HT
Round Termination
6
7
/
8
"*
RTL-8DM
RTL-8HT
Round Termination
7
3
/
4
"*
RTT-8DM
RTT-8HT
Round Termination
with Slip Section
6
7
/
8
" to
3
1
/
8
"*
RTTL-8DM
RTTL-8HT
Round Termination
with Slip Section
8
1
/
" to
1
1
/
"*
ET-8DM
ET-8HT
Square Chase-Top
12"*
ETO-8DM
Square Chase-Top
with Mesh
12"*
ETL-8DM
ETL-8HT
Square Chase-Top
with Slip Section
7" to 15"*
ETLO-8DM
Square Chase-Top
with Mesh & Slip
Section
12" to
5
1
/
"*
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
sured to the flue gas outlet height.
Hemmed
End
End
8" Stainless
Inner Pipe
Inner Pipe
1
3
/
8
"
Galvanized
Outer Pipe
Outer Pipe
Figure 7 - Outside Air Kit
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
or Straps (Min. of 1/4" x 20" in size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
Location
Must Allow
For Bushes
or Snow
Vent Hood
Required for
Wall Installation
Required for
Wall Installation
Air Inlet
Eyebrow
Eyebrow
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
(Check Local Codes
Before Installing in a
Vented Crawl Space)
VenTing inSTallaTion
OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)
(MODEL AK4/AK4F)
Installation of outside air kit should be per-
formed during rough framing of fireplace due
to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 24 on page 15 for instruction of
operating air kit.
formed during rough framing of fireplace due
to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 24 on page 15 for instruction of
operating air kit.
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
The maximum height for the
air vent can not exceed 3 feet
below the flue gas outlet of the
termination.
CHIMNEY PIPE
DESA Heating, LLC chimney system con-
sists of 12", 18", 24", 36" and 48" snap-lock,
double-wall pipe segments, planned for
maximum adaptability to individual site re-
quirements. Actual lengths gained after fitting
overlaps must be taken into consideration
(lineal gain) and are given in lineal gain chart
(see Figure 8).
Lineal gain is actual measurable length of a
part after two or more parts are connected.
sists of 12", 18", 24", 36" and 48" snap-lock,
double-wall pipe segments, planned for
maximum adaptability to individual site re-
quirements. Actual lengths gained after fitting
overlaps must be taken into consideration
(lineal gain) and are given in lineal gain chart
(see Figure 8).
Lineal gain is actual measurable length of a
part after two or more parts are connected.
WARNING: The opening in
collar around chimney at top of
fireplace must not be obstructed.
Never use blown insulation to fill
chimney enclosure.