TROUbLEShOOTING 
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle, or similar object to clean 
pilot. This can damage pilot unit.
The two most common causes of a malfunctioning gas appliance are:
1.  Loose wiring connections
2.  Construction debris clogging the pilot and/or gas control valve filter
Note:
 Before troubleshooting the system, make sure the gas shutoff valve is ON.
OBSERVED PROBLEM
Ignitor will not spark or pilot will 
not light
POSSIBLE CAUSE
1. No gas supply, or shutoff valve 
is OFF
2. Air in gas line
3. Construction debris clogging 
pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control  valve  knob  is  not 
opening
7. No power to unit or the igni-
tion module or power trans-
former is bad
8. Vent damper not fully open
REMEDY
1. Check to see if you have gas 
supply  and  that  equipment 
shutoff valve is opened
2. Repeat lighting procedure sev-
eral times to purge all air out of 
lines. If after repeated attempts 
appliance does not light, call for 
qualified service and repair.
3. Remove debris and dirt, in-
spect  and  clean  any  other 
possible obstructions
4. Contact your gas supplier to 
check pressure
5. Have  a  qualified  technician 
replace pilot line
6. Replace control valve (Refer to 
Replacement Parts, page 38)
7. Check that main power is on 
and that all wire connections are 
made correctly to the ignition 
model (see Wiring Diagram
page 27). Check for 24 VAC at 
the secondary side of the trans-
former. If 24 VAC is present, 
and module does not operate, 
have module replaced otherwise 
have transformer replaced.
8. Open vent damper until fully 
locked in OPEN position
CLEANING AND MAINTENANCE
Continued
vENTING SYSTEM
Conduct annual inspection of the venting system 
following these guidelines:
1.  Check areas of venting system that are ex-
posed to the weather for corrosion (rust spots 
or streaks and, in extreme cases, holes). Have 
these items replaced immediately by a quali-
fied service person.
2.  Remove the vent cap and shine a flashlight 
into the vent. Remove any foreign material.
3.  Check for evidence of excessive condensation. 
Continuous condensation can cause corrosion 
of caps, pipes, and fittings and can be caused 
by having excessive lateral runs, too many 
elbows, or exterior portions of the system 
being exposed to cold weather.
4.  Inspect joints to verify that no pipe section or 
fitting has been disturbed and loosened. Check 
mechanical supports such as wall straps for 
rigidity.