Installation
Only For Qualified Installers
Preliminary steps to prepare for the installation of 
the ShadowLight XL Fireplace Insert
Remove the chimney cap if one exists so that the flue 
may be cleaned and the venting installed.
Remove any existing hearth accessories such as glass 
doors, spark screens, andirons, and grates. 
Clean the chimney thoroughly to remove ash, soot, 
and any obstructions, and then clean ash, soot, dust, 
and debris from the fireplace.
The  damper  must  be  locked  open  to  allow  the  3" 
venting to pass through. If it is necessary to modify 
the damper area to allow passage of the venting, the 
modifications  should  be  allowed  under  local  codes. 
Confirm  any  planned  changes  with  local  building 
officials.
Use Only Approved Venting
Observe local codes when venting the ShadowLight 
XL. If no local codes exist, follow ANSI Z21.88-2002 
installation code.
Do not connect the venting to the flue of a chimney that 
serves a separate solid-fuel burning appliance.
The  venting  manufacturer's  installation  instructions 
must be followed exactly.
The most efficient venting systems are those that have 
a minimum number of bends and minimal horizontal 
runs.
WARNING:  Operation  of  this  heater  when  not 
connected  to  a  properly  installed  and  maintained 
venting system can result in carbon monoxide (CO) 
poisoning and possible death.
Exhaust restrictor plates must be installed depending 
on type of gas and chimney height. See page 20 to 
determine restrictor. 
Venting
“Warning: Failure to position parts in accordance 
with these diagrams or failure to use only parts 
specifically approved with this appliance may 
result in property damage or personal injury.”