Specifications 
Leveling Bolt
Vent
Air Intake
On-Off  
Thermostat 
Switch
On-Off
Thermostat 
Switch 
Connector
 
      
RATINGS           
 
 
 
 
NATURAL    
 PROPANE 
 
Input Rating (Btu/hr)(0-2,000 ft)(0-610m)                
 
35,000 BTU    
35,000 BTU 
Input Rating(Btu/hr)(2000-4500ft)(610-1375m)  
 
 
34,000 BTU   
34,500 BTU   
Min. Input Rating (Btu/hr) 
 
 
 
 
         21,600 BTU     
20,900 BTU    
Orifices (DMS)(0-2000 ft)(0-610m)   
  
 
 
31 
 
 
50
Orifices (DMS)(2000-4500ft)(610-1375m)   
 
 
33 
 
 
51
Manifold Pressure (in w.c./kPa) 
 
 
 
 
3.5 / .87 
 
10.0 / 2.49
Minimum Manifold Pressure (in w.c./kPa)   
 
 
1.3 / .32 
 
3.6 / 0.9
Minimum Inlet Pressure (in w.c./kPa)  
 
 
 
5.0 / 1.25 
         11.0 / 2.74
Maximum Output (BTU/hr)(0 to 4,500 ft.)(0 to 1,375 m)(Blower off) 27,600  
28,600
7