Johnson Controls R-410A Benutzerhandbuch
R-410A
SPLIT-SYSTEM
AIR-COOLED CONDENSING UNITS
AND AIR HANDLERS
SPLIT-SYSTEM
AIR-COOLED CONDENSING UNITS
AND AIR HANDLERS
YH-07 thru -20 and YJ-10 thru -20
CONDENSING UNIT MODELS
PH-07 thru -20 and PJ-15 thru -20
HEAT PUMP UNIT MODELS
NH-07 thru -20 and NJ-10 thru -20
AIR HANDLING UNIT MODELS
7.5 - 20 Ton
60 Hertz
60 Hertz
TECHNICAL
GUIDE
TECHNICAL
GUIDE
505430-BTG-A-0309
ISO 9001
Certified Quality
Management System
NH/NJ Air Handlers
YH/YJ/PH Outdoor Units
YH/YJ/PH/PJ Outdoor Units
Description
UP condensing units and heat pumps are completely assembled,
piped and wired at the factory to provide a single-piece unit for
shipment and rigging. Each unit is pressurized with a holding charge of
refrigerant R-410A for storage and/or shipping.
piped and wired at the factory to provide a single-piece unit for
shipment and rigging. Each unit is pressurized with a holding charge of
refrigerant R-410A for storage and/or shipping.
The compact design, clean styling, small footprint, and quiet operation
make these condensing units and heat pumps suitable for almost any
outdoor location. On rooftops... because they weigh much less than a
single package unit of similar capacity and are much easier to rig and
support. On the ground... because the footprint is compact allowing a
variety of applications.
make these condensing units and heat pumps suitable for almost any
outdoor location. On rooftops... because they weigh much less than a
single package unit of similar capacity and are much easier to rig and
support. On the ground... because the footprint is compact allowing a
variety of applications.
Both the UP condensing units and heat pumps are equipped with
reliable Simplicity® microprocessor controls to assure proper
operation and unit protection for long product life. Products from 7 to
20 tons are available in single or dual (2 or 4 pipe) refrigerant circuits
for redundancy in operation and various application choices such as
one outdoor unit matched with two indoor units.
reliable Simplicity® microprocessor controls to assure proper
operation and unit protection for long product life. Products from 7 to
20 tons are available in single or dual (2 or 4 pipe) refrigerant circuits
for redundancy in operation and various application choices such as
one outdoor unit matched with two indoor units.
The UP air handling units are completely assembled units, including a
well-insulated cabinet, a DX cooling coil with copper tubing, aluminum
fins, expansion valve(s), distributor(s), 2” throwaway filters, a
centrifugal blower, a blower motor, an adjustable belt drive, a blower
motor contactor and a small holding charge of refrigerant R-410A.
well-insulated cabinet, a DX cooling coil with copper tubing, aluminum
fins, expansion valve(s), distributor(s), 2” throwaway filters, a
centrifugal blower, a blower motor, an adjustable belt drive, a blower
motor contactor and a small holding charge of refrigerant R-410A.
Units are shipped in the vertical position ready for field installation, but
can be easily converted to horizontal position. An added benefit of the
UP air handling units is they are designed to operate with either a
condensing unit or a heat pump and no field modification or special
unit is required for heat pump applications.
can be easily converted to horizontal position. An added benefit of the
UP air handling units is they are designed to operate with either a
condensing unit or a heat pump and no field modification or special
unit is required for heat pump applications.