STORAGE
OPERATION
Continued
CHECKING FOR LEAKS
1.  Turn heater valve to OFF position.
2.  Turn  cylinder  supply  valve  fully  counter 
clockwise to OPEN position.
.  Use a noncorrosive leak detection solution 
to check the connection for leaks before 
attempting to light heater. If leak is found, 
turn cylinder valve to CLOSE and do not 
use until all leaks are corrected.
LIGHTING INSTRUCTIONS
Gas Light
1.  Press power switch to ON, gas light will 
automatically light.
2.  Press  power  switch  to  OFF  to  turn  gas 
light off.
.  To  turn  off  gas  supply  to  gas  light,  turn 
knob  on  manual  shutoff  valve  to  OFF. 
Manual  shutoff  valve  is  located  on  gas 
train assembly inside of heater cabinet.
Note: Be sure manual shutoff valve is in the 
ON position to operate gas light.
Main Burner
1.  Push heater control knob in and turn coun-
ter clockwise to the START position.
2.  Push  control  knob  in  and  press  ignitor 
button. Repeat until heater is lit.
.  Continue  holding  knob  in  for  approxi-
mately 0 seconds. Heater should remain 
lit in the LOW heat setting.
4.  For  more  heat,  press  knob  and  rotate 
counterclockwise to HIGH setting.
5.  If RELIGHTING, wait 5 minutes for heater 
to cool and gas to clear, then follow steps 
1 through .
SHUTDOWN INSTRUCTIONS
1.  Press control knob and rotate clockwise 
to OFF position.
2.  Close propane/LP cylinder valve (rotate 
knob clockwise).
BURNER OPERATION
Visually inspect burner for proper operation. 
The burner should glow red with a minimum 
amount of flame lap after initial firing. If flame 
lap on burner is excessive, have heater ser-
viced. Pressure may be too high or nozzle/
burner may be damaged.
Figure 11 - Burner Operation 
Correct 
Flame 
Pattern
Incorrect 
Flame 
Pattern
I G N I T O R
G A S  L I G H T
P O W E R  S W I T C H
OFF
START-LOW
H I G H
ON
OFF
Figure 10 - Gas Light Heater Controls
 CAUTION: Disconnect heater 
from propane/LP supply cylinder.
1.  Do  not  store  heater  while  attached  to 
propane/LP cylinder. Close cylinder valve. 
Remove  the  hose/regulator  assembly 
from the propane/LP cylinder by turning 
the fuel gas connector nut clockwise. 
2.  Storage  of  heater  inside  is  permissible 
only  if  the  cylinder  is  disconnected  and 
removed from the appliance.
3.  Store propane/LP cylinder in safe manner. 
Refer to Chapter 5 of Standard for Storage 
and Handling of Liquefied Petroleum Gases, 
ANSI/NFPA  58.
  Follow  all  local  codes. 
Cylinders  must  be  stored  outdoors  in  a 
well-ventilated area out of reach of children. 
Disconnected cylinders must have threaded 
valve  plugs  tightly  installed,  and  must  not 
be  stored  in  a  building,  garage  or  any 
other enclosed area. Never store cylinders 
near  high  heat,  open  flame,  or  where 
temperatures exceed 100° F (38° C). 
4.  Store in a dry, clean, and safe place.