SPECIFICATIONS
REMOTE-READY MODELS
VGC18PR
•  Rating (Variable): 24,000/30,000 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Manifold Pressure: 7.9" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 14" W.C., Min* - 11" W.C.
VGC18NR
•  Rating (Variable): 21,000/30,000 Btu/Hr
•  Type Gas: Natural
•  Ignition: Electronic
•  Manifold Pressure: 3.4" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 10.5" W.C., Min* - 5" W.C.
VGC24PR
•  Rating (Variable): 25,000/36,000 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Manifold Pressure: 7.9" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 14" W.C., Min* - 11" W.C.
VGC24NR
•  Rating (Variable): 25,000/36,000 Btu/Hr
•  Type Gas: Natural
•  Ignition: Electronic
•  Manifold Pressure: 3.4" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
VGC30PR
•  Rating (Variable): 25,000/36,000 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Manifold Pressure: 7.9" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 14" W.C., Min* - 11" W.C.
VGC30NR
•  Rating (Variable): 25,000/36,000 Btu/Hr
•  Type Gas: Natural
•  Ignition: Electronic
•  Manifold Pressure: 3.4" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
SERVICE HINTS
When Gas pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-
tact your local propane/LP or natural gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESA 
Heating Products’ Technical Service Department 
at 1-866-672-6040. When calling please have your 
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ techni-
cal services web site at www.desatech.com.
REPLACEMENT PARTS
Note:
 Use only original replacement parts. This 
will protect  your  warranty  coverage  for  parts 
replaced under warranty. 
pARTS UNDER WARRANTY
Contact authorized  dealers  of  this  product.  If 
they can’t supply original replacement part(s), 
call DESA Heating Products’ Technical Service 
Department at 1-866-672-6040.
When  calling  DESA  Heating  Products,  have 
ready
•  your name
•  your address
•  model and serial numbers of your heater 
•  how heater was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 
factory.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they 
can’t supply original replacement part(s), call 
DESA Heating Products at 1-866-672-6040 for 
referral information.
When  calling  DESA  Heating  Products,  have 
ready
•  model number of your heater 
•  the replacement part number