Desa LSL18NT Benutzerhandbuch

Seite von 56
www.desatech.com
116292-01A
16
Figure 24 - Correct Burner Flame Pattern 
Yellow 
Tipping
Figure 25 - Incorrect Burner Flame 
Pattern 
1
/
2
 
Deflector 
Height
Blue 
Flame
1
/
2
 
Deflector 
Height
Note:
 The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This may not always agree with room tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.). Frequent use of your heater will 
let you determine your own comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 6, page 9).
2.  Follow steps 1 through 7 under Lighting 
Instructions,
 page 15.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights. 
4.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control  knob.  Now  follow  step  9,  under 
Lighting Instructions
, page 15.
5.  Replace front panel.
INSPECTING HEATER 
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure  22  shows  a  correct  pilot  flame  pattern. 
Figure 23 shows an incorrect pilot flame pattern. 
The  incorrect  pilot  flame  is  not  touching  the 
thermocouple. This will cause the thermocouple 
to cool. When the thermocouple cools, the heater 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 23
•  turn heater off (see To Turn Off Gas to Appliance, 
page 15)
•  see Troubleshooting, page 18
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 24 - Incorrect Pilot Flame Pattern
Figure 23 - Correct Pilot Flame Pattern
Thermocouple
Pilot 
Burner
Thermocouple
Blue Flame
Yellow Flame
Pilot 
Burner
OPERATING HEATER
Continued
BURNER FLAME PATTERN
 WARNING: If yellow tipping 
occurs, your heater could pro-
duce increased levels of carbon 
monoxide.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles enter the 
heater  and  burn  causing  brief 
patches of orange flame. 
Figure 24 shows a correct burner flame pattern. 
Figure 25 shows an incorrect burner flame pattern. 
The incorrect burner flame pattern shows yellow 
tipping of the flame. It also shows the flame higher 
than 1/2 the deflector panel height.
If burner flame pattern is incorrect, as shown in 
Figure 25
•  turn heater off (see To Turn Off Gas To Appli-
ance
, page 15)
•  see Troubleshooting, page 18