Desa LSL18PT Benutzerhandbuch

Seite von 56
www.desatech.com
116292-01A
4
6.  Keep all air openings in front and bottom of 
heater clear and free of debris. This will insure 
enough air for proper combustion. 
7.  If heater shuts off, do not relight until you 
provide  fresh,  outside  air.  If  heater  keeps 
shutting off, have it serviced.
8.  Do not run heater
•  where flammable liquids or vapors are used 
or stored
•  under dusty conditions
9.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
10.  Do not use heater if any part has been under 
water. Immediately call a qualified service 
technician to inspect the room heater and to 
replace any part of the control system and any 
gas control which has been under water. 
11.  Turn off and let cool before servicing. Only 
a qualified service person should service and 
repair heater. 
12.  Operating heater above elevations of 4,500 
feet (1,371 m) could cause pilot outage. 
13.  To prevent performance problems, do not use 
propane/LP fuel tank of less than 100 lbs. (45 kg) 
capacity.
14.  Provide  adequate  clearances  around  air 
openings.
LOCAL CODES
Install and use heater with care. Follow all lo-
cal codes. In the absence of local codes, use the 
latest edition of National Fuel Gas Code, ANSI 
Z223.1/NFPA 54*
.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
SAFETY INFORMATION
Continued
Figure 1 - Vent-Free Gas Heater
Ignitor
Control Knob 
(under door)
Heater Cabinet
Glass Panel
PRODUCT 
IDENTIFICATION
UNPACKING
1.  Remove heater from carton.
2.  Remove all protective packaging applied to 
heater for shipment.
3.  Check  heater  for  any  shipping  damage.  If 
heater is damaged, promptly inform dealer 
where you bought heater.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS/pilot is a required feature for vent-free room 
heaters. The ODS/pilot shuts off the heater if there 
is not enough fresh air.
IGNITION SYSTEM
This heater has either a piezo ignitor or electronic 
ignitor to light heater fuel supply.
THERMOSTATIC HEAT CONTROL
Thermostat  models  have  a  thermostat  sensing 
bulb and a control valve. This results in the great-
est heater comfort. This can also result in lower 
gas bills.