OPTIONAL POSITIONING 
OF THERMOSTAT 
SENSING bULb
(Thermostat-Controlled Models Only)
FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE
If your log set cycles to pilot, but the room tem-
perature drops to a lower than ideal comfort level 
before the log set comes back on, you may want 
to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located on the gas 
valve assembly. This location allows the ther-
mostat to keep the room temperature at an ideal 
comfort level for most fireplace applications. For 
positioning the thermostat sensing bulb elsewhere, 
an adhesive-backed mounting clip is available 
(see Figure 42).
Tools needed: 5/16" hex driver or socket 
1.  Locate the gas valve assembly and thermostat 
sensing bulb (see Figure 43). 
2.  With 5/16” hex driver or socket, loosen the 
thermostat screw. Carefully slide the thermo-
stat sensing bulb out of the retaining clamp 
(see Figure 44). 
  Note: Do not remove the screw. Make sure 
you  tighten  the  screw  after  removing  the 
thermostat sensing bulb. 
  IMPORTANT:  Do  not  force  or  bend  the 
thermostat sensing bulb or capillary. 
Capillary 
Screw
Retaining Clamp 
Thermostat 
Sensing Bulb 
Figure 43 - Location of Gas Valve 
Assembly and Thermostat Sensing Bulb 
Thermostat 
Sensing Bulb 
Gas Valve 
Assembly 
Figure 42 - Adhesive-backed Mounting 
Clip 
Figure 44 - Removing Thermostat 
Sensing Bulb 
Figure 45 - Locating Thermostat Sensing 
Bulb on Masonry Fireplace 
Figure 46 - Locating Thermostat Sensing 
Bulb on Factory-built Metal Fireplace 
Adhesive-backed 
Mounting Clip 
Thermostat 
Sensing Bulb 
Figure 47 - Installing Thermostat Sensing 
Bulb Behind Glass Doors 
Adhesive-
backed 
Mounting Clip 
Glass Doors 
Thermostat 
Sensing Bulb 
Adhesive-backed 
Mounting Clip 
Thermostat 
Sensing Bulb 
(Unit Will 
Differ From 
Illustration)
(Unit Will 
Differ From 
Illustration)
3.  The thermostat sensing bulb may be located 
to the lower right front side of fireplace. De-
termine location of sensing bulb, but do not 
mount sensing bulb until step 4. If you have a 
masonry fireplace, see Figure 45 for location. 
  If you have a factory-built metal fireplace, see 
Figure 46 for location. 
  If your fireplace has glass doors, position 
sensing bulb directly behind door gap on right 
bottom side (see Figure 47).