Desa VTN25R Benutzerhandbuch

Seite von 48
www.desatech.com
113261-01C
4
5.  This heater needs fresh, outside air ventilation 
to run properly. This heater has an Oxygen 
Depletion  Sensing  (ODS)  safety  shutoff 
system. The ODS shuts down the heater if 
not enough fresh air is available. See Air for 
Combustion and Ventilation, page 5.
6.  Keep all air openings in front and bottom of 
heater clear and free of debris. This will insure 
enough air for proper combustion. 
7.  If heater shuts off, do not relight until you 
provide  fresh,  outside  air.  If  heater  keeps 
shutting off, have it serviced.
8.  Do not run heater
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
9.  Do not use heater if any part has been under 
water. Immediately call a qualified service 
technician to inspect the room heater and to 
replace any part of the control system and any 
gas control which has been under water. 
10.  Turn off heater and let cool before servicing. 
Only a qualified service person should service 
and repair heater. 
11.  Operating heater above elevations of 4,500 
feet (1372 m) could cause pilot outage.
12.  To  prevent  performance  problems,  do  not 
use propane/LP fuel tank of less than 100 
psi (690 kPa) capacity.
13.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
14.  Provide  adequate  clearances  around  air 
openings.
LOCAL CODES
Install and use heater with care. Follow all local 
codes. In the absence of local codes, use the latest 
edition of The  National  Fuel  Gas  Code, ANSI 
Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
SAFETY INFORMATION
Continued
Figure 1 - Infrared Tower Heater
UNPACKING
1.  Remove heater from carton.
2.  Remove all protective packaging applied to 
heater for shipment.
3.  Check  heater  for  any  shipping  damage.  If 
heater is damaged, promptly contact the dealer 
to where you bought heater.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS/pilot is a required feature for vent-free room 
heaters. The ODS/pilot shuts off the heater if there 
is not enough fresh air.
IGNITION SYSTEM
This heater has an electronic ignitor to light heater 
fuel supply, which requires a AAA battery.
THERMOSTATIC HEAT CONTROL
Your unit is thermostatically controlled when heat-
er and remote control are set to the proper modes. 
This results in the greatest heater comfort.
PRODUCT 
IDENTIFICATION
Electronic 
Ignitor
Grill
Plaque 
(behind 
Grill)
On/Pilot/Off Knob
Manual/Auxiliary 
Knob