Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Flame
Yellow Flame
Figure 27 - Correct Pilot Flame Pattern
Figure 28 - Incorrect Pilot Flame Pattern
Figure 29 - Correct Burner Flame Pattern 
INSPECTING HEATER
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure 27  shows  a  correct  pilot  flame  pattern. 
Figure 28 shows an incorrect pilot flame pattern. 
The  incorrect  pilot  flame  is  not  touching  the 
thermocouple. This will cause the thermocouple 
to cool. When the thermocouple cools, the heater 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 28
•  turn heater off (see  To Turn Off Gas to Ap-
pliance,
  page  15  or  17,  depending  on  your 
model) 
•  see Troubleshooting, page 20
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 30 - Incorrect Burner Flame 
Pattern 
BURNER FLAME PATTERN
Figure 29 shows a correct burner flame pattern. Fig-
ure 30 shows an incorrect burner flame pattern. 
If burner flame pattern is incorrect, as shown in 
Figure 30
•  turn heater off (see  To Turn Off Gas to Ap-
pliance,
  page  15  or  17,  depending  on  your 
model) 
•  see Troubleshooting, page 20