FUELS
  WARNING:  Use  only  kero-
sene, #1/#2 diesel/fuel oil, JET A 
or JP-8 fuels to avoid risk of fire or 
explosion. Never use gasoline, oil 
drained from crankcases, naph-
tha,  paint  thinners,  alcohol  or 
other highly flammable fuels.
Use only kerosene, #1/#2 diesel/fuel oil, JET A or 
JP-8 fuels. Heavier fuels such as No. 2 fuel oil or No. 
2 diesel fuel may also be used but will result in:
•  noticeable odor
•  additional fuel filter maintenance
•  the need for nontoxic, anti-icer additives in very 
cold weather
Do  not  use  fuels  heavier  than  No.  2  grade  or 
heavy oils such as oil drained from crankcases. 
These heavy oils will not ignite properly and will 
contaminate the heater.
IMPORTANT:
 Use a KEROSENE ONLY (blue) or 
DIESEL ONLY (yellow) storage container. Be sure 
storage container is clean. Foreign matter such as rust, 
dirt or water will cause the ignition control assembly 
to shut down heater. Foreign matter may also require 
heaterʼs fuel system to be frequently cleaned.
THEORY OF OPERATION
The Fuel System:
 The air pump forces air through the air line. The air is then pushed through the 
nozzle. This air causes fuel to be lifted from the tank. A fine mist of fuel is sprayed into the combus-
tion chamber.
The Air System: 
The motor turns the fan. The fan pushes air into and around the combustion chamber. 
This air is heated and provides a stream of clean, hot air.
The Ignition System: 
The ignition control assembly provides power to the ignitor. This ignites the 
fuel/air mixture in the combustion chamber.
The Flame-Out Control System:
 This system causes the heater to shut down if the flame goes out.
Figure 5 - Cross Section Operational View
Clean 
Heated 
Air Out
Fuel 
Filter
Air Line 
To Burner
Air Output Filter
Air Pump
Air Intake Filter
Cool Air In
Fan
Combustion Chamber
Ignitor 
Ignition Control 
Assembly
Air For Fuel 
System
Air For 
Combustion
And Heating
Fuel
Nozzle
Fuel 
Tank
VENTILATION
 WARNING: Provide a fresh air 
opening of at least three square 
feet (2,800 square cm) for each 
100,000  Btu/hr  rating.  Provide 
extra  fresh  air  if  more  heaters 
are  being  used.  The  minimum 
ventilation  requirements  must 
be  followed  to  avoid  risks  as-
sociated with carbon monoxide 
poisoning.  Make  certain  these 
requirements  are  met  prior  to 
operating heater.
Example:
 A 200,000 Btu/Hr (58.6 kw) heater 
requires one of the following:
•  a two-car garage door [16 feet (4.88 meter) 
opening] raised 5 inches (12.7 cm)
•  a single-car garage door [9 feet (2.74 meter) 
opening] raised 8 inches (20.3 cm)
•  two, 30 inch (76.2 cm) windows raised 15 inches 
(38.1 cm)
Motor