TROUBLESHOOTING
 WARNING: Never service heater while it is plugged in, operating, 
or hot. Severe burns and electrical shock can occur.
REMEDY
1. Check circuit breaker in elec-
trical panel
2. Turn  thermostat  knob  to  a 
higher setting
3. Check all electrical connec-
tions. See Wiring Diagrams
page 15
4. If fan does not turn freely, see 
Pump Rotor, page 14
5. Replace  ignition  control  as-
sembly
6. Replace motor
1. Fill tank with kerosene
2. See  Pump  Pressure Adjust-
ment, page 10
3. See Fuel Filter, page 11
4. See Nozzle Assembly, page 12
5. Drain and flush fuel tank with 
clean kerosene. See Storing, 
Transporting,  or  Shipping
page 7
6. Check electrical connections. 
See Wiring Diagrams , page 15
7. Replace ignitor, see page 11
8. Replace  ignition  control  as-
sembly
1. See  Pump  Pressure Adjust-
ment, page 10
2. See Air Output, Air Intake, and 
Lint Filters, page 10
3. See Fuel Filter, page 11
4. See Nozzle Assembly, page 12
5. Make sure photocell boot is 
properly seated in bracket
6. Clean photocell lens
7. Check electrical connections. 
See Wiring Diagrams, page 15
8. Replace photocell
9. Replace  ignition  control  as-
sembly
POSSIBLE CAUSE
1. No power to heater
2. Thermostat setting is too low
3. Bad electrical connection be-
tween motor and ignition con-
trol assembly or ignition control 
assembly and power cord
4. Binding pump rotor
5. Defective ignition control as-
sembly
6. Defective motor
1. No fuel in tank
2. Pump pressure incorrect
3. Dirty fuel filter
4. Obstruction in nozzle
5. Water in fuel tank
6. Bad  electrical  connection 
between ignitor and ignition 
control assembly
7. Defective ignitor
8. Defective ignition control as-
sembly
1. Pump pressure incorrect
2. Dirty  air  intake,  air  output, 
and/or lint filter
3. Dirty fuel filter
4. Obstruction in nozzle
5. Photocell assembly not properly 
installed (not seeing the flame)
6. Dirty photocell lens
7. Bad electrical connection be-
tween photocell and ignition 
control assembly
8. Defective photocell
9. Defective ignition control as-
sembly
FAULT CONDITION
Motor does not start five seconds 
after heater is plugged in
Motor starts and runs but heater 
does not ignite
Heater ignites but ignition control 
assembly shuts heater off after a 
short period of time
 WARNING: High voltage!
 WARNING: High voltage!
 WARNING: High voltage!