11 Device Information
1
Type and order code 
LIK 8MER
2
Design
2.1
Model
 Compact
2.2
Degree of protection according to EN 60 529 for compact devices
and heating components
 IP 20
2.3
Installation location
 Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
°C / °C
 Up to 58 / above 18
Cooling, flow
°C
+7 to +20
Air (heating)
°C
-25 to +35
Air (cooling)
°C
+15 to +40
3.2
Temperature spread of heating water at A7 / W35
10.0
5.0
3.3
Heat output / COP 
at A-7 / W35 
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning:  External temperature 2 °C
and heating water flow temperature 55 °C.
 5.8 / 2.7
5.5 / 2.6
at A-7 / W45 
kW / ---
5.4 / 2.1
at A2 / W35 
kW / ---
 7.5 / 3.3
7.4 / 3..2
at A7 / W35 
kW / ---
 9.3 / 3,9
9.2 / 3.8
at A7 / W45 
kW / ---
8.8 / 3.2
at A10 / W35 
kW / ---
 9.8 / 4.1
9.7 / 4.0
3.4
Temperature spread of cooling water at A35 / W7
7.5
5.0
3.5
Cooling capacity / COP
at A27 / W7
kW / ---
7.9 / 2.7
7.9 / 2.6
at A27 / W18
kW / ---
9.6 / 3.2
9.6 / 3.2
at A35 / W7
kW / ---
7.0 / 2.0
6.9 / 2.0
at A35 / W18
kW / ---
8.5 / 2.4
8.5 / 2.4
3.6
Sound power level device / outdoors
dB(A) 
 53 / 60
3.7
Sound pressure level at a distance of 1 m (indoors)
dB(A)
48.0
3.8
Heating water flow with an internal pressure differential of 
2
m³/h / Pa
2. The heat circulating pump is integrated.
 0.8 / 2700
1.6 / 11900
3.9
Free pressure, heating circulating pump (heating, max. stage)Pa
45000
27000
3.10 Cooling water flow with an internal pressure differential of m³/h / Pa
0.8 / 2700
1.2 / 6500
3.11 Free pressure, circulating pump (cooling, max. stage)
Pa
45000
37000
3.12 Air flow rate with an external static pressure differential of  m³/h / Pa
 2500 / 20
3.13 Refrigerant; total filling weight
type / kg
 R404A / 3.3
3.14 Output of electric heating element (second heat generator)kW
 2.0
4
Dimensions, connections and weight
4.1
Device dimensions 
H x W x L cm
 190 x 75 x 68
4.2
Device connections to heating system
Inch
 G 1'' external
4.3
Air duct inlet and outlet (min. internal dimensions)
L x W cm
 44 x 44
4.4
Weight of the transportable unit(s) incl. packing
kg
 250
4.5
Buffer tank volume
l
 50
4.6
Buffer tank pressure rating
bar
 6
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
230 / 20
5.2
Nominal power consumption 
 A2 W35
kW
2.27
2.33
5.3
Starting current with soft starter
A
30
5.4
Nominal current A2 W35 / cos 
ϕ
A / ---
12.3 / 0.8
12.7 / 0.8
6
Complies with the European safety regulations
3
3. See CE declaration of conformity
7
Additional model features
7.1
Defrosting
 Automatic
Type of defrosting
Reverse cycle
Defrosting tray included 
Yes (heated)
7.2
Heating water in device protected against freezing 
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
 Yes
7.3
Performance levels
 1
7.4
Controller internal/external 
Internal