Dimplex LA 26PS Benutzerhandbuch

Seite von 26
www.dimplex.de
E-9
English
11
11 Device Information
1
Type and order code 
LA 17PS
LA 22PS
LA 26PS
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
 IP 24
 IP 24
 IP 24
2.2
Installation Location
Outdoors
Outdoors
Outdoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow 
1
°C / °C
1. See operating limits diagram 
Up to 65 / above 18
Up to 65 / above 18
Up to 65 / above 18
Air
°C
-20 to +35
-20 to +35
-20 to +35
3.2
Temperature spread of heating water at A7 / W35
9.3
5.0
9.5
5.0
9.4
5.0
3.3
Heat output / COP 
at A-7 / W35 
2
kW / ---
3
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
3. Operation with 1 compressors
6.7 / 2.5
6.4 / 2.4
7.7 / 2.4
7.5 / 2.3
8.7 / 2.4
8.4 / 2.2
4
4. Operation with 2 compressors
11.4 / 2.6
10.8 / 2.5
13.6 / 2.6
13.1 / 2.5
14.4 / 2.6
13.9 / 2.5
at A-7 / W45 
kW / ---
6.0 / 2.2
7.0 / 2.2
7.8 / 2.3
10.3 / 2.2
12.5 / 2.3
13.3 / 2.3
at A2 / W35 
kW / ---
8.7 / 3.2
8.3 / 3.0
10.6 / 3.1
10.5 / 3.0
11.7 / 3.1
11.5 / 3.0
14.5 / 3.1
14.3 / 3.0
16.7 / 3.1
16.5 / 3.0
18.8 / 3.1
18.6 / 3.0
at A7 / W35 
kW / ---
10.1 / 3.6
9.6 / 3.4
12.6 / 3.8
12.0 / 3.6
13.7 / 3.6
13.3 / 3.5
17.3 / 3.5
16.6 / 3.4
22.0 / 3.8
21.1 / 3.5
24.0 / 3.7
22.9 / 3.5
at A7 / W45 
kW / ---
9.3 / 2.9
11.3 / 3.0
12.5 / 2.9
16.1 / 2.9
20.5 / 3.0
21.6 / 3.0
at A10 / W35 
kW / ---
11.8 / 4.1
11.4 / 4.1
13.7 / 4.2
13.5 / 4.1
15.0 / 4.1
14.7 / 4.0
19.6 / 3.8
19.2 / 3.8
23.4 / 4.0
23.2 / 3.9
26.2 / 4.0
25.9 / 4.0
3.4
Sound power level
dB(A)
64
68
68
3.5
Sound pressure level at a distance of 10 m (air outlet side) dB(A)
37
41
41
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
1.6 / 2900 3.0 / 10000 2.0 / 4500 3.5 / 13800 2.2 / 3100 3.8 / 8900
3.7
Air flow rate
m³/h 
5500
8000
8000
3.8
Refrigerant; total filling weight
type / kg
R290 / 1.8
R290 / 2.2
R290 / 2.5
4
Dimensions, connections and weight
4.1
Device dimensions 
H x W x L cm
157 x 155 x 85
171 x 168 x 100
171 x 168 x 100
4.2
Device connections to heating system
Inch
G 1 1/4'' external
G 1 1/4'' external
G 1 1/4'' external
4.3
Weight of the transportable unit(s) incl. packing
kg
330
360
371
5
Electrical connection
5.1
Nominal voltage; fuse protection
V / A
400 / 20 T
400 / 20 T
400 / 25 T
5.2
Nominal power consumption 
 A2 W35
kW
4.74
4.76
5.4
5.5
6.1
6.2
5.3
Starting current with soft starter
A
23
25
30
5.4
Nominal current A2 W35 / cos 
ϕ
A / ---
8.6 / 0.8
8.6 / 0.8
9.8 / 0.8
9.9 / 0.8
11.1 / 0.8
11.2 / 0.8
6
Complies with the European safety regulations
5
5. See CE declaration of conformity
7
Additional model features
7.1
Defrosting
Automatic
Automatic
Automatic
Type of defrosting
Hot gas
Hot gas
Hot gas
Defrosting tray included 
Yes (heated)
Yes (heated)
Yes (heated)
7.2
Heating water in device protected against icing 
6
6. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
Yes
Yes
7.3
Performance levels
2
2
2
7.4
Controller internal/external 
External
External
External