SPECIFICATIONS
-Performance/Size/Weight-
-Water/Electrical Requirements-
All  A-Voltage 120 heaters with model numbers ending in “B”, MCA  = 33
120 - Heating Only Models 
 
120AHDE 
120BHDE 
120DHDT 
120HHDT
 
BTU - 80%RH 
 
 
 
 
Air ºF  / Water ºF…80/80 
109,000 
109,000 
95,000 
95,000 
COP 5.6 
5.6 
5.5 
5.5 
Voltage/Hz/Phase 208-230/60/1 
208-230/60/3 
380-415/50/3 
200-240/50/1 
Min. Circuit Ampacity 
38 
27 
13 
37 
Max. Fuse or Breaker 
60 
45 
20 
60 
Rec. Fuse or Breaker 
40 
30 
15 
40 
Min-Max Water Flow (gpm) 
20-70 20-70 
20-70 20-70 
Shipping weight (lbs) 
323 
323 
323 
323 
Shipping Size (l x w x h) 
40" X 36" X 44" 
40" X 36" X 44"
 
40" X 36" X 44"
 
40" X 36" X 44"
 
Uncrated Weight (lbs) 
296 
296
 
296
 
296
 
Uncrated Size (l x w x h) 
34” X 31” X 39” 
34” X 31” X 39”
 
34” X 31” X 39”
 
34” X 31” X 39”
 
*
 
120 – Heat & Cool Models (Reversing) 
 
120ARDE 
120BRDE 
120DRDT 
120HRDT
 
BTU - 80%RH 
 
 
 
 
Air ºF  / Water ºF…80/80 
103,000 
103,000 
92,000 
92,000 
COP 5.4 
5.6 
5.4 
5.4 
Voltage/Hz/Phase 208-230/60/1 
208-230/60/3 
380-415/50/3 
200-240/50/1 
Min. Circuit Ampacity 
38 
27 
13 
37 
Max. Fuse or Breaker 
60 
45 
20 
60 
Rec. Fuse or Breaker 
40 
30 
15 
40 
Min-Max Water Flow (gpm) 
20-70 20-70 
20-70 20-70 
Shipping weight (lbs) 
330 
330 
330 
330 
Shipping Size (l x w x h) 
40" X 36" X 44" 
40" X 36" X 44"
 
40" X 36" X 44"
 
40" X 36" X 44"
 
Uncrated Weight (lbs) 
303 
303
 
303
 
303
 
Uncrated Size (l x w x h) 
34” X 31” X 39” 
34” X 31” X 39”
 
34” X 31” X 39”
 
34” X 31” X 39”
 
*