Haier HSU-09LEK13/R2(DB) Benutzerhandbuch

Seite von 8
Normal
Performance
inspection
Noise is heard
Phenomenon
Cause or check points
The system does not restart
immediately.
Smells are generated.
Mist or steam are blown out.
Multiple
check
Poor cooling
Application temp. range of air conditioner -7
o
C~43
o
C.
When unit is stopped, it won't restart 
elapsed to protect the system.
When the electric plug is pulled out 
and reinserted, the protection circuit 
During unit operation or at stop, 
a swishing or gurgling noise may 
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is 
temperature changes.
Should there be a big noise from
 filter may be too dirty.
This is because the system 
circulates smells from the interior
During COOL or DRY operation, 
This is due to the sudden cooling
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before 
Is temperature set correctly?
Are there some doors or 
Is there any direct sunlight
through the window during the 
Are there too much heat sources
or too many people in the room 
In dry mode, fan 
speed can’t be changed.
In DRY mode, when room 
than temp.setting+2
o
C,unit will 
regardless of FAN setting.
Maximum: D.B
10.The appliance must be installed on a strong enough support.
9.Young children should be supervised ensure that they do not 
play with the appliance.
8.The appliance is not intended to use by young children or infirm
persons without supervision.
7.The used batteries should be disposed of properly.
6. After installation, the power plug should be easily reached.
5.The wiring method should be in line with the local wiring standard.
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
11.The wiring diagram is attached inside the machine.
2. If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or a similar qualified person.
The type of connecting wire is H05RN-F or H07RN-F
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Cooling
Indoor
Outdoor
Maximum: D.B / W.B
32
o
C/23
o
C
18
o
C/14
o
C
43
o
C/26
o
C
18
o
C
Minimum:  D.B / W.B
Minimum:  D.B
For:  T3
Cooling
Indoor
Outdoor
Maximum: D.B / W.B
Minimum: D.B / W.B
Maximum: D.B / W.B
Minimum: D.B
29
o
C/19
o
C
18
o
C/14
o
C
54
o
C/24
o
C
18
o
C
For:  T1
during cooling operation?
cooling operation?(Use curtain)
 windows left open?
 inlet and outlet?
Normally it should be cleaned 
every 15 days.
run intermittently at LOW speed 
temperature becomeslower 
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture,
paint, cigarettes.
air flow in unit operation, air 
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. 
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
If the fuse of outdoor unit on PC board is broken, please change
it with the type of T. 25A/250V.
Application temp. range of air conditioner -7
o
C~54
o
C.
T1:
T3:
Trouble shooting
 Cautions
Before asking for service, check the following 
first.
4.The distance between the indoor unit and the floor should be
more than 2m.
7