7.4  Safety Requirements 
       for Electric 
      Appliances 
7.5  Earthing
       Requirements
7.3  Outdoor Unit 
       Installation Position 
       Selection 
       (Continued)
7.6  Others
6. Make sure that the outdoor unit installation dimension 
    should accord with installation dimension diagram,
    convenient for maintenance, repair. ( See Pg.23)
7. The height difference of connecting the tubing within 5m, 
    the length of connecting the tubing within 10m.
8. Select a place where it is not reachable for the children.
9. Select a place where will not block the passage and do 
    not influence the city appearance.
1. The power supply should be used the rated voltage and 
AC exclusive circuit, the power cable diameter should be 
    satisfied.
2. Voltage applying range: the normal running range is rated
voltage 198V - 253V.
3. Don't drag the power cable emphatically.
4. It should be reliable eearthd and it should be connected to 
    the special earth device, the installation work should be
     operated by the professional.
5. The min. distance from the unit and combustive surface is 
    1.5m.
• The creepage protect switch and air switch with enough
     capacity must be installed in the fixing circuit.
• Air switch (thermal-magnetic breaker) can protect the short
   circuit and overload.
• The power supply position should be 
correctly connected, and  that should be
reliably connected, no internal short circuit. 
Wrong connection, may cause fire.
1. Air conditioner is type 1 electric appliance, thus please do 
    conduct reliable earthing measure.
2. The yellow-green two-color wire in air conditioner is 
    earthing wire and cannot be used for other purpose. It 
    cannot be cut off and be fix it by screw, otherwise it would
    cause electric shock.
3. The user power must offer the reliable earthing terminal.
    DO NOT connect the earthing wire with the bellow places:
    - Gas pipe
 - Tap water pipe
    - Contamination pipe
    - Other places that the professional personnel consider
       them unreliable.
1. The connection method of unit and power cable as well as 
    the interconnection method of each isolated component 
    should refer to the circuit diagram stick on the unit.
2. The model of the blown fuse and rated value should refer
    to the silk-screen on the controller or fuse sleeve.
3. The outside static pressure is 0MPa when the unit is 
    testing.
NOTE
7.  NOTICES FOR INSTALLATION
Installation Service