Appendix: Installation
1. SUMMARY
1.1 Notice
This operation manual has explicit information for 
installation and maintenance in most conditions. Contact 
the local distributor or after-sales service for further 
information.
1) Wiring notice
   Only qualified professionals should carry out wiring of the 
appliance.
   Disconnect the power supply before completion of wiring, 
piping or checking the appliance.
    Voltages generated by the appliance is fatal.
Read the electrical schematic diagram and explanation 
before installation. Improper installation and earth 
connection may result in fatal injury.
    C onnect the earth as required by local regulations.
  Tightly fasten all the wiring connections to prevent 
overheating or fire.
   Special power, switches and sockets are required for the 
power supply of the appliance.
   Electric meter capacity must be larger than or equivalent to 
16A.
Remark per EMC Directive 89/336/EEC
To prevent flicker impression during the start of the 
compressor (Technical Process) and the adversely influence 
nd
caused by the 2  harmonics of compressor following 
installation conditions do apply
1. The power connection for  the air conditioner has to be done 
at the main power distribution. This distribution has to be of a 
low impedance is reached at 32A fusing point.
2. No other equipment has to be connected to this power line.
3. For the detailed installation acceptance please refer to your 
contract with the power supplier, if restrictions do apply for 
products like washing machines, air conditioners or electrical 
ovens.
4. For the details of the power of air conditioner, please refer to 
the rating plate of the product.
5. For any question contact your local dealer.
2). Transport
    C arefully move the outdoor unit.
3). Installation
----When the appliance is mounted to the ceiling or the wall,
    Make sure that the ceiling or the wall is strong enough for the 
appliance.
   Make a wood or metal frame to support the appliance if 
necessary.
----When the appliance is mounted in a room,
    Properly insulate the outdoor unit, and make sure there is no 
moisture on the appliance or on the floor.
----When the appliance is installed on a damp or uneven area,
   Make a flat concrete base and place the base under the 
outdoor unit.
----When the appliance is installed in an area of strong winds.
    Using firm bolts and metal frames to fix the properly covered 
outdoor unit.
----When the appliance (Model Heat Pump) is installed in an 
area of heavy snow.
   The outdoor unit must be installed in a position above the 
snow accumulation.
4). Connection
    Use the shortest tubes possible
    Using a flaring method
   Smear some refrigeration oil between the flared surface and the 
connected tube.
   Fasten the nuts with a torque wrench to prevent leakage of 
refrigerant.
    Check for leakage before trial operation.
5). Maintenance
    Disconnect   the   power     before    checking    the    electrical 
     components and the circuits.
    Avoid contact with the moving parts of the appliance.
    Clea r the site and make sure there is no installation debris left in 
the appliance.
6). Other
    Keep the room well ventilated during installation.
1.2 Installing instruction
Read the operation manual before installation and keep this 
manual in a safe place.
1)Tools
1. Screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Steel ruler
5. Spirit level
6. Hammer
7. Percussion drill
8. Tube cutter
9. Pipe flarer
10. Pipe bender
11. Adjustable spanner
2)  Attachment
     (see the packing list)
3) Parts Package
Copper tubes, components and insulation materials for the 
outdoor unit.
4) Type of the copper tube and insulation materials
1. Table 1 indicates that tubes should be cut with an additional 
length of 30cm-40cm, to reduce the vibration from the outdoor unit.
 
  
                         Narrow tube
                         Wide tube
ITEM
       Outside Diameter       Thickness      Outside Diameter   Thickness
 KF-5002GWE
                
6.35mm
        0.8mm     
12.7mm
      0.8mm
2. The insulation materials for the copper tubes should conform to 
the required length and the wall thickness should not be less than 
8mm.
3. Insulated copper wires should be used for wiring and the 
specification should depend on the length.
5) Additional materials for installation
1. white tape
2. nails or clips (as required)
3. putty
4. refrigeration oil
5. clips for fixing refrigerant tubes
22