Sanyo KH3672R / C3672R Benutzerhandbuch

Seite von 180
1
2
3
4
5
6
I-27
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
XH2672R
Source
230 - 208 VAC / 1 phase / 60 Hz
Remote  controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 VAC, 5 A
Fan (Number … diameter)
in.
(mm)
Turbo (1…17-7/16 (443))
Fan motor
Model
SFG6X - 41D6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High)
rpm
6 … 464
Nominal output
W
40
Coil resistance
Ω
BRW - WHT
: 170.3
,
ORG - YEL
:
43.2
(Ambient temperature 68 
°F)
WHT - VLT
:
18.1
,
WHT - PNK
:
83.5
VLT
- ORG
:
43.2
,
YEL
- BLK
:
60.2
Safety device
Operating temperature
Open
°F
266
    ±  14.4
Close
°F
174.2
± 27
Run capacitor
VAC,
µF
440 V , 4.5 
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows … Fins per inch
2 … 14.9
Face area
ft.
2
(m
2
)
3.69 (0.343)
Panel
Model No.
PNR - XH2442
Auto louver motor
MT8 - 3C
Auto louver motor … Rated
V, W,
rpm
240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 
°F)
Ω
16.430 
Ω ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE