Desa 000 BTU TB103 Benutzerhandbuch

Seite von 56
www.desatech.com
119143-01A
5
PROPANE SUPPLy
Propane/LP gas and propane/LP tank(s) are 
to be furnished by the user.
Use this heater only with a propane/LP vapor 
withdrawal  supply  system.  See  Chapter  5 
of  the  Standard  for  Storage  and  Handling 
of Liquefied Petroleum Gas, ANSI/NFPA 58
 
and the Natural Gas and Propane Installation 
Code CSA B149.1
. Your local library or fire 
department will have these booklets.
The amount of propane/LP gas ready for use 
from  propane/LP  tanks  varies.  Two  factors 
decide this amount:
1.  The amount of propane gas in tank(s)
.  The temperature of tank(s)
The chart below shows the number of 100 lb 
(45 kg) tanks needed to run this heater.
 
 
number of tanks
 
Temperature 
Models
 
at tank location 
55  85  125/170
  above 0° F (-7° C) 
 0° F (-7° C) to -0 (-18° C)  1 
 
3
Less gas is vaporized at lower temperatures. 
You may need a larger tank in colder weather. 
Your local propane/LP gas dealer will help you 
select the proper supply system.
VENTILATION
 warninG: Follow the mini-
mum fresh, outside air ventila-
tion  requirements.  If  proper 
fresh, outside air ventilation is 
not provided, carbon monoxide 
poisoning  can  occur.  Provide 
proper fresh, outside air ventila-
tion before running heater.
Provide  a  fresh  air  opening  of  at  least 
three square feet for each 100,000 Btu/Hr 
(105,500 k/j) rating. Provide extra fresh air 
if more heaters are being used.
INSTALLATION
 warninG: review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
 warninG: Test all gas piping 
and connections for leaks after 
installing or servicing. never use 
an open flame to check for a leak. 
Apply a mixture of liquid soap 
and water to all joints. Bubbles 
forming show a leak. Correct all 
leaks at once.
1.  Provide propane/LP supply system (see 
Propane/LP Supply).
2.  Connect  POL  fitting  on  hose/regulator 
assembly  to  propane/LP  tank(s).  Turn 
POL fitting counterclockwise into threads 
on  tank.  Tighten  firmly  using  a  wrench. 
IMPORTANT: Tighten regulator with vent 
pointing  down.  Pointing  vent  down  pro-
tects regulator from weather damage.
3.  Connect hose to inlet connector of heater. 
Tighten firmly using a wrench.
 
IMPORTANT: Extra hose or piping may be 
used if needed. Install extra hose or piping 
between propane/LP tank and regulator. 
You must ensure a minimum of 25 psig 
at the inlet of the regulator. You must use 
the regulator supplied with the heater.
Propane 
Tank
Hose
Regulator
Vent (pointing 
down)
Fuel Gas 
Connector
Supply 
Valve
Figure 5 - Regulator With Vent Pointing 
Down
To 
Heater 
Inlet 
Connector
POL Fitting