SPECIFICATIONS
Model Size  
160-IF 
280-IF 
Maximum Output Rating (Btu/Hr) 
158,000 
278,000
Net Output Rating (Btu/Hr) 
133,000 
234,400
Fuel 
Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*
Fuel Tank Capacity (U.S. Gal./Liters) 
17/65 
28/105 
Fuel Consumption 
(Gal. Per Hr/Liters Per Hr) 
1.27/4.81 
2.22/8.40 
Pump Pressure (psi) 
145 
174 
Electric Requirements 
120 V/60 HZ (Same Both Models)
Amperage (Normal Run) 
4.8 
8.5 
Motor RPM 
2850 
3490
Hot Air Output (CFM) 
1,060 
1,940
Shipping Weight 
190/86 
320/145
 
(Approximate lbs./kg)
Heater Weight without Fuel 
161/74 
273/124 
 
(Approximate lbs./kg)
* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter main-
tenance. Use in extreme cold temperatures may require nontoxic anti-icer additives.
TECHNICAL SERVICE
You my have further questions about installation, 
operation or troubleshooting. If so, contact DESA 
Heating Productsʼ Technical Service Department 
at 1-866-672-6040. When calling please have your 
model and serial numbers of your heater ready. You 
can also visit DESA Heating Productsʼ technical 
services web site at 
www.desatech.com
.
ACCESSORIES
Purchase accessories and parts from your nearest 
dealer or service center. If they can not supply 
these  accessories  or  parts,  either  contact  your 
nearest parts dealer or DESA Heating Products 
at 1-866-672-6040 for referral information. Parts 
Centrals are listed in the Authorized Service Center 
booklet supplied with heater.
FLEXIBLE VENT 
HOSE
HA3220 for Model 160-IF 
Model 160-IF can only con-
nect  one  20'  section  of  vent 
hose. Must be used wih hose 
connector kit HA3230.
HA3221 for Model 280-IF
Model 280-IF can connect up to two 20' sections 
of vent hose. Must be used wih hose connector 
kit HA3231.
HOSE CONNECTOR KIT
HA3230 for Model 160-IF
HA3231 for Model 280-IF
EXTERNAL THERMOSTAT - HA3210
EXTREME COLD FUEL OIL PRE-HEATER 
HA3211