Installation Instructions
HOW TO CONNECT
ELECTRICAL SUBBASE
CONNECTION
Remove the room cabinet.
Connect to electrical power.
Review the following steps for applicable supply
voltages. 
Reinstall the room cabinet.
Tandem
15 Amp.
230/208-volt receptacle configuration.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
Power cords may include an arc fault interruption or
a leakage current detection interruption device. A
test and reset button is provided on the plug case or
the inline case. The device should be tested on a
periodic basis by first pressing the TEST button and
then the RESET button. If the TEST button does 
not trip or if the RESET button will not stay engaged,
discontinue use of the Zoneline and contact a
qualified service technician.
230/208-volt models may be installed using one of
the following electrical subbases:
*Not approved for use on 7000 BTU models.
Electrical subbases provide an enclosure for direct
connection or enclosed receptacles. The subbase kit
includes the power cord.
The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is
done in accordance with these instructions and all
electrical codes.
Branch Circuit and
Proper GE
Unit Amperage Rating
Subbase Kit
15
RAK204D15P
20
RAK204D20P
30
RAK204D30P*
A power supply kit must be used to supply power to the
Zoneline unit. The appropriate kit is determined by the
voltage, the means of electrical connection and the
amperage of the branch circuit.
Connections of 208 or 230-volt circuits may be with a
power supply kit or a junction box kit. 
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Local codes may require
the use of an arc fault or leakage current detection
device on the power cord. Be sure to select the
correct cord for your installation.
Power supply kit
Branch Circuit and
Proper GE Power Cord
Unit Amperage Rating
with LCDI Device
15
RAK3153
20
RAK3203
30
RAK3303*
230/208 VOLT ELECTRICAL CONNECTION OPTIONS
*Not approved for use on 7000 BTU models.
POWER CORD
CONNECTION
DIRECT CONNECTION
Order the following Kit for 230/208-volt direct
connection as required:
Skip to the “MAKE ELECTRICAL CONNECTION TO
THE UNIT” section.
Branch Circuit and
Power Supply
Power
Unit Amperage Rating
Accessory
Supply Kit
15
RAK4002A
RAK4157
20
RAK4002A
RAK4207
30
RAK4002A
RAK4307
13