Auxiliary Controls on your Zoneline.
ge.com
Auxiliary Controls—Dip Switches
The auxiliary dip switch controls are located
behind the room cabinet, through an opening 
in the control panel.
Remove the room cabinet. See the To Remove the
Room Cabinet section.
The owner is responsible for checking switches
and ensuring they are in the desired position.
HIGH
COOL
1
2
3
4
5
6
1
2
3
4
5
6
7
8
UP
DOWN
UP
DOWN
ALLI
2
R (All Electric Heat)
(3900 Series models only)
C: FAN CN (Cooling–Smart Fan)
H: FAN CY (Heating–Smart Fan)
CLASS 2 (Remote Thermostat)
LOAD SHEDDING (CDC)
FREEZ Sen (Freeze Sentinel)
CONST FAN (Constant ON Fan)
No Function (Reserved for future use)
TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)
TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)
7
8
Heat Sentinel
HEAT BOOST 
(3900 Series models only)
Safety Instructions
Operating Instructions
Care and Cleaning
Tr
oubleshooting T
ips
Consumer Support
All Electric Heat
This electric heat option functions only on the
3900 Series models. When this switch is enabled
(UP), heat pump operation is locked out, causing
the unit to provide only electric resistance heat.
Cooling—Smart Fan
When this switch is enabled (UP), it allows the
indoor fan to cycle on/off with the compressor.
When this switch is disabled (DOWN),  it allows 
the indoor fan to run continuously. 
Heating—Smart Fan
When this switch is enabled (UP), it allows the
indoor fan to run continuously. When this 
switch is disabled (DOWN),  it allows the indoor 
fan to cycle on/off with the heat pump or 
heater operation.
ALLI
2
R (All Electric Heat)
C: FAN CN (Cooling–Smart Fan)
H: FAN CY (Heating–Smart Fan)
Dip Switches
Access Cover
Remote Thermostat—Class 2
When this switch is enabled (UP), it allows the
unit to operate with a Class 2 Remote Control
Wall Thermostat. The unit controls are disabled.
CLASS 2 (Remote Thermostat)
5