4
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. 
Proper installation is your responsibility. Make sure you have 
everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the 
power cord exits the air conditioner. 
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation 
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air 
conditioner weighs 51 lb (23 kg) to 65 lb (29.5 kg).
NOTES:
Cabinet louvers must not be obstructed. Air must be able to 
pass freely through the cabinet louvers. 
Your model may differ from the one shown.
Window Installation
Window opening measurements: 
25" (63.5 cm) minimum to 38" (96.5 cm) maximum opening 
width
14" (35.6 cm) minimum opening height
Electrical Requirements
The electrical ratings for your air conditioner are listed on the 
model and serial number label. The model and serial number 
label is located behind the front panel above the coil area. 
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
A. Cabinet louvers
A. 25" (63.5 cm) minimum
B. 14" (35.6 cm) minimum 
A
A
B
Power supply cord 
Wiring requirements
115 volt (103.5 min. - 
126.5 max.)
0-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit 
only.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.