Friedrich MW30C3F Benutzerhandbuch

Seite von 27
1
2006.03.15
SPECIFICATIONS
INDOOR UNIT
MW30C3F
OUTDOOR UNIT
MR30C3F
COOLING CAPACITY
30,700 BTU/hr
POWER SOURCE
208 V / 230 V
FREQUENCY
60 Hz
RUNNING CURRENT
15.2 A
INPUT WATTS
3,460 W
SEER
15.0
MOISTURE REMOVAL
9.7 Pts/hr (4.6 L/hr)
AIR CIRCULATION-High
647 cfm (1,100 m
3
/hr)
ELECTRICAL DATA
COMPRESSOR
FAN MOTOR
DIMENSIONS
TYPE
Hermetic motor compressor,
4 poles, Rotary type
DISCRIMINATION
POWER SOURCE
5KD240XAD21
208 V / 230 V 60Hz
REFRIGERANT
R-410A
4 lb.10 oz ( 2,100 g )
POWER SOURCE
208 V / 230 V
HIGH
1,330 r.p.m.
1,120 r.p.m.
940 r.p.m.
830 r.p.m.
850 r.p.m.
INDOOR UNIT
MED
LOW
QUIET
OUTDOOR UNIT
INDOOR UNIT
H x W x D
H x W x D
12-5/8 x 39-1/4 x 9 inch
OUTDOOR UNIT
NOISE LEVEL
HIGH
47 dB
41 dB
36 dB
32 dB
53 dB
INDOOR UNIT
MED
LOW
QUIET
OUTDOOR UNIT
REFRIGERANT CHARGE (R410A)
20 m
4 lb. 10 oz. (2,100 g)
5 lb. 8 oz. (2,500 g)
6 lb. 6 oz. (2,900 g)
7 lb. 4 oz. (3,300 g)
40 g/m
FULL CHARGE
Pipe length
30 m
40 m
50 m
ADDITIONAL CHARGE
WEIGHT
INDOOR UNIT
Gross / Net
Gross / Net
40 / 31 lbs. (18 / 14 kg )
OUTDOOR UNIT
155 / 137 lbs. (70 / 62 kg )
320 x 998 x 228 mm
32-3/4 x 35-3/8 x 13 inch