Friedrich CP14 Benutzerhandbuch

Seite von 16
9
2. Using #10 x 
⁷⁄₈" pan-head Phillips screws, attach bracket to 
cabinet. Repeat for other bracket.
3. Loosen locking nut and turn the adjustment bolt (C) for each 
bracket until the bolt touches the wall (B).
4. Tighten the locking nut on adjustment bolt to lock in position.
Complete Installation
1. Insert seal behind the top of the lower window sash and 
against the glass of the upper window (B).
2. Place one window-lock bracket on top of lower window and 
against upper window sash on each side of window (A). 
3. Use a 
³⁄₃₂" drill bit to drill a starter holes through the holes in 
each bracket into the window sash. 
4. Attach both window-lock brackets to window sash with #10 x 
³⁄₄" round-head screws to secure window in place.
Through-the-Wall Cabinet Installation
NOTES:
Handle air conditioner gently.  
Be sure your air conditioner cabinet does not fall out of the 
opening during installation or removal. 
The place where the power cord exits the air conditioner 
should be no more than 4 ft (122 cm) from a grounded 
3 prong outlet.
It is the customer's responsibility and obligation to have this 
product installed by a qualified technician familiar with 
through-the-wall room air conditioner installations.
Do not block the louvers on the front panel.
Do not block the louvers on the outside of the air conditioner.
Option 1—Wood, metal or plastic molding
When using a wood, metal or plastic molding, the wood frame 
should line up with inside wall as shown.
Option 2—Plastered wall with no molding
If the plastered wall is to be flush with the cabinet and no molding 
is used, the wood frame must be set 
¹⁄₂" (13 mm) into the inside 
wall.
Install Wood Frame
1. Construct wood frame. See “Location Requirements” for 
dimensions.
2. Measure outside width and height of frame to determine wall 
opening dimensions. 
3. Cut opening through the wall. Remove and save insulation.
NOTES: 
Dimension for depth depends on wall thickness and type 
of molding. 
Do not block louvers in air conditioner cabinet.
A. Support bracket
B. Locking nut
C. Adjustment bolt
A
B
C
A. Window lock brackets
B. Window rail seal 
C. Upper window glass
A
B
C
A
A. Trim Molding
B. Inside wall
C. Wood wall framing
D. Louvers
A
C
B
D
A. Plastered wall
B. Inside wall
C. Wood frame
D. Louvers
D
A
C
B
surface