Toshiba RAV-SM1400UT-E Benutzerhandbuch

Seite von 80
72
INST
ALLA
TION MANU
AL
85464359426000 (EN)
T
o
 P
e
rsonnel Char
g
ed in Installation 
W
ork and Ser
vice
Remote Contr
oller 
Wireless Kit
MODEL :
  TCB-AX21U (W)-E
Ho
w to install the sensor
s
*
The positions where the sensors can be installed are limited to the
cor
ners (
A
) in Fig.
 1.
  
Theref
ore
, f
or installation of the sensor units
,
consider the direction when a panel is installed to the indoor unit.
1.
Remo
v
e
 the suction gr
ille.
2.
T
a
k
e
 off the scre
w fixing the cor
ner cap and remo
v
e
 the cor
ner cap
sliding it side-w
ard.
 (Fig.
 2)
Fig. 1
Fig. 2
3.
The ther
mal insulation mater
ial is stuff
ed in the square hole
pro
vided to pass through cab
les of the panel, so tak
e off it once
and pass the cab
le out of the sensor of wireless remote controller
through the gr
ille
. Using a clamp
, fix the cab
le with scre
ws and
then be sure to stuff again the remo
v
ed ther
mal insulation mater
ial
as or
iginal.
 (Fig.
 3)
If the ther
mal insulation mater
ial is not stuff
ed, de
wing ma
y
happen.
Fig. 3
4.
After cab
ling according to 
“Ho
w to perf
o
rm cab
ling of sensor units
”,
remain the cab
le length enough to remo
v
e
 the sensor unit and fix it
with scre
ws using a clamp
. (Fig.
 3)
5.
Install the sensor units to the panel.
 In this time
, slide the panel so
that the hooks are fit in completely at 3 positions.
And also be careful not to pinch the cab
le.
 (Fig.
 4)
Fig. 4
NO
TES :
1.
A
v
oid to twist the cab
les of the operation section with cab
les of the
p
o
w
er supply
, etc.
 It causes a malfunction.
2.
When noise is contained to the po
wer supply of the indoor unit,
counter measures such as mounting the noise filter is necessar
y.
Ho
w to perf
orm cab
ling of sensor units
Connection dia
gram
T
o
 operate a gr
oup contr
ol of m
ultiple indoor units by 2 remote
contr
oller
s
*
Master and Sub remote controllers are oper
a
b
le e
v
en if the
y are
installed to an
y indoor unit.
(T
otal cab
le length:
 Within 200m)
Ho
w to set the r
oom temperature 
sensor
The room temperature sensors are equipped in the indoor unit and
the wireless remote controller
. One of two sensors w
o
rk
s
.
The room temper
ature sensor is set to the indoor unit side at the
shipment from the f
actor
y.
 T
o
 select the sensor in the remote
controller
, push the SENSOR b
utton (Right figure) inside of the
remote controller co
v
er and chec
k
 “
Main sensor
” disappears from
LCD
.
Ho
w to set the ad
dress s
witc
h
When the m
ultiple sensors are installed in the same room, an
address can be set to pre
v
ent cross comm
unication.
When replacing the batter
y and pushing SET b
utton, the address of
the remote controller becomes [ALL] and the sensor is enab
led to
receiv
e signal regardless of setting of address s
witch of the
oper
ation section.
F
or selecting of the remote controller address
, ref
er to Owner
’s
Man
ual.
Change the address of the sensor b
y
 remo
ving scre
ws of P
.C
. board
co
v
er of the sensor unit.
 After then, fix the co
v
er with screws using
a clamp
.
Slide s
witc
h
Chec
k the slide s
witch in the batter
y bo
x of the remote controller is
set to [S] / [A] at shipment from the f
actor
y.
Do not change the setting.
T
est run
Ho
w to use [TEST]
1.
T
u
rn
 No
.1 of DIP s
witch [S003] on sensor P
.C
. board from OFF to
ON.
2.
Dur
ing the test r
un, all the indication lamps on LCD flash.
3.
Dur
ing the test r
un, the temper
ature cannot be controlled.
4.
After the test r
un, be
sure to tur
n DIP s
witch 1
from ON to OFF and
chec
k the indication
lamps do not flash.
Use [TEST] function
only f
or a test r
un,
otherwise the unit is
ov
e
rloaded.
 Fix the
co
v
er as or
iginal.
Ho
w to 
handle 
the 
remote 
contr
oller
In case using remote contr
oller mounting to the wall,
 etc.
Chec
k a signal is receiv
ed correctly b
y
 pushing 
 b
utton 
at 
the
position to be fix
ed.
Cautions f
or installation of the remote contr
oller
T
o
 operate the remote controller b
y
 fixing it to the wall, etc.
 with a
remote controller holder
, tur
n on the fluorescent lamp
, oper
ate the
remote controller at the position to be fix
ed, chec
k the air condi-
tioner nor
mally oper
ates
, and then mount it.
When the room temperature is sensed b
y
 the remote controller
,
mount the remote controller pa
ying attention to the f
ollo
wing items
.
Place not e
xposed directly to cold or hot wind.
Place not e
xposed directly to the sunlight.
Other places where the remote controller is not influenced.
Explanation to customer
s
Hand ov
er the 
“Owner
’s Manual
” and 
“Installation Manuals
” to the
customer after installation wo
rk
s
.
Explain usage and maintenance of the remote controller according
to 
“Owner
’s Manual
”.
Lamp indication
No indication e
ven if
the remote controller
is oper
ated.
Cause
P
o
w
er supply is not
tur
ned on.
Miscab
ling betw
een
sensor unit and indoor
unit
Def
ectiv
e connection
betw
een sensor unit
and indoor unit
Miscab
ling or def
ectiv
e
connection between
indoor and outdoor
units
Protectiv
e de
vice of
outdoor unit w
o
rk
s
.
Protectiv
e de
vice of
indoor unit w
o
rk
s
.
Measures
Che
c
k
 cab
le
connection
and correct it.
Chec
k
outdoor unit.
Chec
k
indoor unit.
Self-dia
gnosis tab
le and measures
Lamp indication
of sensor
:
Goes off
:
Flash
(0.5-sec.
inter
v
a
l)
Drain pipe side
of indoor unit
Refr
igerant pipe
side of indoor unit
Sensor unit
installing position 
A
(Right side of electr
ic
par
ts bo
x)
Electr
ic par
ts bo
of indoor unit
Scre
w
Cor
ner cap
Cor
ner cap
Ceiling panel
Slid
Remo
v
e
 the ther
mal insulation 
mater
ial, fix the cab
le with scre
ws 
using a clamp
, and put in the 
ther
mal insulation mater
ial again.
Connection
Connect the cab
les out of the sensor unit to the ter
minal b
loc
k f
o
r
remote controller cab
ling of the indoor unit.
  (There is no polar
ity
.)
CN001
2P White
Indoor unit
Sensor unit P
.C
. board
T
e
rminal b
loc
k f
or 
remote controller 
cab
ling
White
Blac
k
Ea
rt
h
Wireless 
remote controller kit
(Master)
CN1
Wired 
remote controller
(Sub)
2
1
(Sold separately)
(Sold separately)
T
e
rminal b
loc
k f
or 
remote controller cab
le
Remote controller cab
le
(Procured locally)
(0.5 to 2mm
²)
Indoor unit
2
1
Sensor 
unit
Ear
th
Ear
th
Ear
th
(Sold  separately)
(Sold  separately)
T
e
rminal b
loc
for remote  controller cab
le
Remote controller inter-unit  cab
le f
or group control
(Procured locally)             (0.5 to 2mm
²)
2
1
Wired 
remote controller
(Sub)
Wireless 
remote controller kit
(Master)
CN1
2
1
In
do
or
 u
n
it 
No
.1
In
do
or
 u
n
it 
No
.2
In
do
or
 u
n
it 
No
.3
Ear
th
In
do
or
 u
n
it 
No
.N
Sensor  unit
NO
TE :
If the room temper
ature data from the
remote controller is not tr
ansmitted to
the unit f
or 10 minutes or more
, the
sensor at indoor unit side is automati-
cally selected e
v
en if the sensor at the
remote controller side is selected.
Fix the remote controller to
ward the
unit as possib
le
.
S001
4
6
S002
3 6
2 5
1 4
Address 
select
Address
S002
3 6
2 5
1 4
Address
S002
3 6
2 5
1 4
Address
S001
4
6
Address 
select
S001
4
6
Address 
select
Displa
y of 
remote 
controller 
address
Address 
s
witch 
position of 
sensor
*
Address s
witch 
of sensor unit 
can be set any 
position.
Address
Address
Address
Address
1
31
31
3
SK
N
AH
C
Select of operation mode
Set to A.
Select of flap indication
Set to S
.
AH
C
SK
N
Flashes alter
nativ
ely
Flashes alter
nativ
ely
1
2
3
4
ON
Sensor 
P
.C
. board
Cor
ner cap
Co
v
e
r
S 003
Bit 1 :
 OFF to ON
1
2
Mounting scre
w
T
russ tapping
4 x 16
T
o
 tak
e off remote controller
pull it tow
ard y
ou.
Put on.
Push.
RESET b
utton
Co
v
e
r
Replacement of batter
y
1.
Holding the both ends of the cov
er and remo
v
e
 it b
y
 sliding
do
wnw
ard.
2.
Correctly inser
t 2 AAA alkali batter
ies matching + and - polar
ities
with indications.
3.
Push SET b
utton with something tipped and attach the co
v
e
r.
Accessor
y par
ts
Requirement
The control b
y
 tw
o remote controllers is enab
led b
y
 installing the
wireless remote controller with the wired remote controller f
or an
indoor unit.
(Max.
 2 remote controllers of wireless or wired are installab
le
.)
“2-remote controllers
” controlling 
means that one or m
ultiple units
are oper
ated b
y
 the m
ultiple remote controllers.
NO
TES :
1.
Upon confir
mation of the ter
minal numbers of the indoor unit,
connect the remote controller cab
les without miscab
ling.
(If applied A
C
 220/230/240 
V
olt, damage the unit.)
2.
The multiple wireless remote controller kits cannot concurrently be
used f
or an indoor unit.
3.
When installing simultaneously the wireless remote controller with
the wired remote controller
, set one of them as the sub remote
controller
.
When setting the wired remote controller as the sub
, e
xchange the
address connector at the rear of P
.C
. board of wired remote
controller from master to sub remote controller
.
When setting the wireless remote controller as the sub
tur
n No
.3 of
DIP s
witch [S003] on P
.C
. board of wireless remote controller
sensor unit from OFF to ON.
T
o
 operate an indoor unit b
y
 2 remote contr
oller
s
*
The indoor unit is oper
ated if either wireless or wired remote
controller is set as master or sub remote controller
.
(T
otal cab
le length:
 Within 400m)
P
a
rt
 Name
Sensor unit
Remote controller
Remote controller
holder
Q
’ty
1
1
1
P
a
rt
 Name
Batter
y
Owner
’s Man
ual
T
apping scre
w
M4 x 16mm
Clamper
Fixing scre
w
M4 x 12mm
Q
’ty
2
1
2
1
1
Ho
w to set the fan motor speed ref
er 
to 
the 
O
WNER
’S MANU
AL