8-2. Outdoor Unit (Inverter Assembly)
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
220
240 V   
50Hz
220
220 V  
60Hz (-E model only)
MICR
O-COMPUTER BLOCK DIA
GRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp. 
sensor
Outdoor air 
temp. sensor
Discharge 
temp. sensor
Indoor unit
send/receive circuit
Relay
circuit
Relay
circuit
Noise
Filter
High Power
factor Correction
circuit
Input current
sensor
•  PWM synthesis function
•  Input current release control
•  IGBT over-current detect control
•  Outdoor fan control
•  High power factor correction control
•  Inverter output frequency control
•  A/D converter function
•  P.M.V. control
•  Discharge temp. control
•  4-way valve control
•  Signal communication to indoor unit
P.M.V.
 : Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way valve
P.M.V.
Inverter
(DC 
®
 AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC 
®
 AC)
Freeze
prevention
heater
Outdoor
Fan motor
Compressor
MCC5009 (P
.C.B)
OUTDOOR UNIT
Current
detect
Current
detect
Converter
(AC 
®
 DC)
Clock 
frequency 
4MHz
(-ND model only)