Toshiba RAS-B10SKVP-E Benutzerhandbuch
– 26 –
8-2. Outdoor Unit (Inverter Assembly)
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
220
–
240 V
~
50Hz
220
–
220 V
~
60Hz (-E model only)
MICR
O-COMPUTER BLOCK DIA
GRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp.
sensor
Outdoor air
temp. sensor
Discharge
temp. sensor
Indoor unit
send/receive circuit
Relay
circuit
Relay
circuit
Noise
Filter
High Power
factor Correction
circuit
Input current
sensor
• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit
P.M.V.
: Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way valve
P.M.V.
Inverter
(DC
®
AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC
®
AC)
Freeze
prevention
heater
Outdoor
Fan motor
Compressor
MCC5009 (P
.C.B)
OUTDOOR UNIT
Current
detect
Current
detect
Converter
(AC
®
DC)
Clock
frequency
4MHz
(-ND model only)