7-2. Operation Data
<Cooling> RAS-M14EAV-E, RAS-M14EACV-E
Temperature
condition
No.of 
operating
units
Operating combination 
(Unit)
Standard
pressure P 
(Mpa)
Heat exchanger
pipe temp.
In-
door 
fan
Out-
door 
fan
compressor
revolution 
(rps)
indoor
outdoor
A
B
T1 (
°
C)
T2 (
°
C)
27 / 19
35 / –
1 unit
10
0.7 to 0.9
11 to 13
43 to 45
High
700rpm
39
13
0.9 to 1.1
8 to 11
47 to 49
High
750rpm
66
2 units
10
10
0.9 to 1.1
14 to 16
47 to 49
High
750rpm
64
13
10
0.9 to 1.1
14 to 16
47 to 49
High
750rpm
65
<Heating> RAS-M14EAV-E
Temperature
condition
No.of 
operating
units
Operating combination 
(Unit)
Standard
pressure P 
(Mpa)
Heat exchanger
pipe temp.
In-
door 
fan
Out-
door 
fan
compressor
revolution 
(rps)
indoor
outdoor
A
B
T1 (
°
C)
T2 (
°
C)
20/–
7/6
1 unit
10
2.2 to 2.4
36 to 38
0 to 2
High
750rpm
60
13
2.5 to 2.7
41 to 43
-1 to 1
High
750rpm
76
2 units
10
10
1.9 to 2.1
30 to 32
-1 to 1
High
750rpm
78
13
10
1.9 to 2.1
30 to 32
-1 to 1
High
750rpm
80
<Cooling> RAS-M18EAV-E, RAS-M18EACV-E
Temperature
condition
No.of 
operating
units
Operating combination 
(Unit)
Standard
pressure P
(Mpa)
Heat exchanger
pipe temp.
In-
door 
fan
Out-
door 
fan
compressor
revolution 
(rps)
indoor
outdoor
A
B
T1 (
°
C)
T2 (
°
C)
27/19
35/–
//
1 unit
10
0.9 to 1.1
11 to 13
41 to 43
High
700rpm
35
13
0.8 to 1.0
8 to 10
45 to 47
High
750rpm
58
16
0.8 to 1.0
7 to 9
47 to 49
High
750rpm
75
2 units
10
10
0.9 to 1.1
11 to 13
48 to 50
High
750rpm
71
13
10
0.9 to 1.1
11 to 13
48 to 50
High
750rpm
71
13
13
0.9 to 1.1
11 to 13
48 to 50
High
750rpm
71
16
10
0.9 to 1.1
11 to 13
48 to 50
High
750rpm
71
<Heating> RAS-M18EAV-E
Temperature
condition
No.of 
operating
units
Operating combination 
(Unit)
Standard
pressure P 
(Mpa)
Heat exchanger
pipe temp.
In-
door 
fan
Out-
door 
fan
compressor
revolution 
(rps)
indoor
outdoor
A
B
T1 (
)
T2 (
)
20/–
7/6
1 unit
10
3.2 to 3.4
44 to 46
0 to 2
High
750rpm
62
13
3.4 to 3.6
50 to 53
0 to 2
High
750rpm
81
16
3.4 to 3.6
51 to 53
0 to 2
High
750rpm
85
2 units
10
10
2.6 to 2.8
37 to 39
-1 to 1
High
750rpm
93
13
10
2.6 to 2.8
38 to 40
-1 to 1
High
750rpm
101
13
13
2.6 to 2.8
38 to 40
-1 to 1
High
750rpm
101
16
10
2.6 to 2.8
38 to 40
-1 to 1
High
750rpm
101
NOTES :
(1)  Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
 
(Thermistor thermometer)
(2)  Connecting piping condition : 7.5meters
×
2 units
°
C
°
C