Toshiba RAS-M16EKCVP-E Benutzerhandbuch

Seite von 136
– 33 –
8-2.
Out
door Unit (In
ver
ter Assembl
y
)
RAS-M14EA
V
-E,
 RAS-M18EA
V
-E (Heat pump models)
RAS-M14EA
CV
-E,
 RAS-M18EA
CV
-E (Cooling-onl
y models)
220–240 V  ~50Hz
220 V  ~60Hz
CONTROL BLOK DIAGRAM (Outdoor unit)
Driver circuit of P.M.V.
Noise
filter
Relay
RY701
Converter
(AC 
 DC)
Input current
sensor
4-way
valve
A unit
P.M.V.
Unit A
send/receive
circuit
Unit B
send/receive
circuit
B unit
P.M.V.
Inverter
(DC 
 AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC 
 AC)
Outdoor
fan motor
Compressor
MCC-5015 (SUB P.C.B)
MCC-5009 (SUB P.C.B)
Current
detect
Current
detect
M.C.U
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• Error displey
• Signal communication to MCU
M.C.U
• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Signal communication to MCU
Gas side pipe 
temp. sensor 
(unit B) (TGb)
Gas side pipe 
temp. sensor 
(unit A) (TGa)
Outdoor Heat-
exchanger temp. 
sensor (TE)
Discharge temp. 
sensor (TD)
Suction temp. 
sensor (TS)
Outdoor air temp. 
sensor (TO)
P.M.V : Pulse Motor Valve
PWM : Pules Width Modulation
IGBT : Insulated Gate Bipolar Transistor
*1
: Heat Pump Model Only
High power factor 
correction circuit
*1