Toshiba RAV-SP1404ATZG-E Benutzerhandbuch
– 62 –
3. Outdoor fan control
Revolution frequency allocation of fan taps [rpm]
3-1) Cooling fan control
The outdoor fan is controlled by TL sensor, TO sensor and the operation frequency.
The outdoor fan is controlled by every 1 tap of DC fan control (14 taps).
The outdoor fan is controlled by every 1 tap of DC fan control (14 taps).
Only for 60 seconds after the operation has started, the maximum fan tap corresponding to the
zone in the following table is fixed and then the fan is controlled by temperature of TL sensor.
zone in the following table is fixed and then the fan is controlled by temperature of TL sensor.
3-2) Heating fan control
The outdoor fan is controlled by TE sensor, TO sensor and the operation frequency.
(Control from minimum W1 to maximum (according to the following table))
(Control from minimum W1 to maximum (according to the following table))
For 3 minutes after the operation has started, the maximum fan tap corresponding to the zone in
the following table is fixed and then the fan is controlled by temperature of TE sensor.
the following table is fixed and then the fan is controlled by temperature of TE sensor.
Object: SP140
Object: SP110
When TE
≥ 24°C continues for 5 minutes, the
compressor stops.
It is the same status as the normal thermostat-
OFF without error display. The compressor
restarts after approx. 2 minutes 30 seconds and
this intermittent operation is not abnormal.
It is the same status as the normal thermostat-
OFF without error display. The compressor
restarts after approx. 2 minutes 30 seconds and
this intermittent operation is not abnormal.
In case that the status in item
generates
frequently, stain on filter of the suction part of the
indoor unit is considered.
Clean the filter and then restart the operation.
indoor unit is considered.
Clean the filter and then restart the operation.
SP110
Up
SP140
Down
W1
W2
W3
W4
W5
W6
W7
W8
W9
WA
WB
WC
WD
WE
200
240
240
260
320
380
480
500
530
610
640
660
720
780
—
—
200
280
360
400
500
520
550
630
660
700
740
820
Temp. range
38°C
≤ TO
29°C
≤ TO < 38°C
15°C
≤ TO < 29°C
5°C
≤ TO < 15°C
0°C
≤ TO < 5°C
–4°C
≤ TO < 0°C
TO < –4°C
TO error
20 Hz
20Hz
45Hz
or lower
to 45Hz
or higher
Min.
Max.
Min.
Max.
Min.
Max.
W6
WC
W8
WC
WA
WD
W5
WB
W7
WC
∗
W9
WC
W4
W8
W6
WA
W8
WC
W3
W6
W5
W8
W7
WA
W2
W4
W4
W6
W5
W8
W2
W3
W3
W5
W4
W6
W1
W2
W1
W4
W2
W6
W1
WC
W1
WC
W2
WD
Temp. range
10°C
≤ TO
5°C
≤ TO < 10°C
–3°C
≤ TO < 5°C
–10°C
≤ TO < –3°C
TO < –10°C
TO error
20 Hz
20Hz
45Hz
or lower
to 45Hz
or higher
Max.
Max.
Max.
W7
W8
W9
W9
WA
WB
WB
WB
WC
WC
WC
WC
WD
WD
WD
WD
WD
WD
Temp. range
10°C
≤ TO
5°C
≤ TO < 10°C
–3°C
≤ TO < 5°C
–10°C
≤ TO < –3°C
TO < –10°C
TO error
20 Hz
20Hz
45Hz
or lower
to 45Hz
or higher
Max.
Max.
Max.
W7
W8
W9
W9
WA
WA
WA
WA
WB
WB
WB
WB
WD
WD
WD
WD
WD
WD
WE tap
+1 tap / 20 sec
Up to the maximum
revolution frequency of each zone
Revolution frequency hold
–1 tap / 20 sec
Up to the minimum
revolution frequency of each zone
TL [˚C]
58
55
38
35
35
–2 taps / 20 sec. (Up to W1)
Stop timer count
+1 tap / 20 sec
(Up to the maximum tap of each zone)
–2 taps / 20 sec. (Up to W1)
–1 tap / 20 sec. (Up to W1)
Revolution frequency hold
TE [˚C]
24
21
18
15
∗ : WB for SP110