8-2.
Outdoor Unit (In
ver
ter Assemb
ly
)
RAS-10GA
VP-E,
 RAS-13GA
VP-E,
 RAS-16GA
VP-E
220–240 V  
~
50Hz
220 V  
~
60Hz
MICRO-COMPUTER BLOCK DIAGRAM
Driver circuit
of P.M.V.
Heat exchanger
temp.sensor
Suction temp. 
sensor
Outdoor air 
temp. sensor
Discharge 
temp. sensor
Indoor unit 
send/receive
circuit
Relay
circuit
Noise
Filter
Converter
(AC 
 DC)
Clock 
frequency 
4MHz
High Power 
factor Correction
circuit
Input current
sensor
•  PWM synthesis function
•  Input current release control
•  IGBT over-current detect control
•  Outdoor fan control
•  High power factor correction control
•  Inverter output frequency control
•  A/D converter function
•  P.M.V. control
•  Discharge temp. control
•  4-way valve control
•  Signal communication to indoor unit
P.M.V.  : Pulse Motor Valve
M.C.U. : Micro Control Unit
M.C.U
For INDOOR UNIT
4-way
valve
P.M.V.
Inverter
(DC 
 AC)
Gate drive
circuit
Gate drive
circuit
Inverter
(DC 
 AC)
Outdoor
Fan motor
Compressor
MCC5009 (P.C.B)
OUTDOOR UNIT
Current 
detect
Current 
detect