GE AZ39H12EAC Merkblatt

Seite von 2
AZ39H12EAC
GE Zoneline
®
 Deluxe Series Heat Pump Unit
Specification Created 2/08
390535
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
Electrical Wiring
All wiring, including installation of receptacle, must be made in accordance with local 
electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) 
RAG63 (Bittersweet)
RAG62 (Maple) 
RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps. 
RAK40 – Deflector Kit to adapt chassis for use with existing  
exterior architectural louvered grilles.
Ducted Applications
2900 and 3900 series can be used with ductwork to heat or cool more than one 
room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct 
Extension is applied to right or left of adaptor. Locally fabricated ductwork may be 
added to extend to maximum recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with  
a junction box and require direct  
connection. (NEC Requires 265V Direct Connection) See Architects and Engineers 
Design Data Manual for electrical  
connection information including use of sub-base for direct connected units. 
Installation must comply with local electrical codes and regulations.
Power Connection kits required on all Zoneline chassis.
Wall Case Dimensions
RAB71 Wall Sleeve
  Heavy-gauge galvanized steel, with insulation.  
  A  – 42", B – 13-3/4", C – 16"
RAB77 Wall Sleeve
  Molded SMC fiberglass-reinforced polyester compound.  
  A – 42-1/8", B– 13-7/8", C – 16-1/4
Wall Opening Dimensions
  Add 1/4" to A and C dimensions for all cut-out size. 
  RAB71 16-1/4" Min. H x 42-1/4" Min. W 
  RAB71 available in 16", 24", 28" and 31" depths 
  RAB77 16-1/2" Min. H x 42-3/8" Min. W
Maximum Cord Extension
SIDE
VIEW
Inside
Room
  Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
265 Volt Sub-Base Connected Units
Sub-Base
Power  
Connection Kit
Electric Heater 
Watts
Electric Heat 
Amps
Min. Circuit 
Protection 
(Amps)
RAK204E15
RAK5172
2,550
10.3
15
RAK204E20
RAK5202
3,450
13.7
20
RAK204E30
RAK5302
5,000
19.6
30
Dimensions and Installation Information (in inches) 
A
C
B
Zoneline RAC Wall Installation