GE AZ58H12DAC Merkblatt

Seite von 2
AZ58H12D – GE Zoneline
®
 Premium Series Heat Pump Unit
Specification Revised 4/06
390566
GE Appliances
Electrical Wiring
All wiring, including installation of receptacle, must be made in  
accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult 
a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 or RAG64 (Beige) 
RAG63 or RAG66 (Bittersweet)
RAG62 or RAG65 (Maple) 
RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps. 
RAK40 – Deflector Kit to adapt chassis for use with existing  
exterior architectural louvered grilles.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt 
units are provided with a junction box and require direct  
connection. (NEC Requires 265V Direct Connection) See 
Architects and Engineers Design Data Manual for electrical  
connection information including use of sub-base for direct  
connected units. Installation must comply with local electrical 
codes and regulations.
Power Connection kits required on all Zoneline chassis.
A
C
B
Zoneline RAC Wall Installation
Zoneline Wall Install QSart
Wall Case Dimensions
RAB71 Wall Sleeve
  Heavy-gauge galvanized steel, with insulation.  
  A  – 42",  B – 13-3/4",  C – 16"
RAB77 Wall Sleeve
  Molded SMC fiberglass-reinforced polyester compound.  
  A – 42-1/8",  B– 13-7/8",  C – 16-1/4
Wall Opening Dimensions
  Add 1/4" to A and C dimensions for all cut-out size. 
  RAB71 16-1/4" Min. H x 42-1/4" Min. W 
  RAB71 available in 16",  24",  28" and 31" depths 
  RAB77 16-1/2" Min. H x 42-3/8" Min. W
Maximum Cord Extension (in inches)
For answers to your Monogram,
®
 GE Profile
 or 
GE
®
 appliance questions, visit our website at
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
SIDE
VIEW
Inside
Room
  Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
230/208 Volt Line Cord Connected Units
Line Cord   
Kit
Electric Heat 
(Btuh)
Electric  
Heater Watts
Electric  
Heat Amps
Min. Circuit 
Protection 
(Amps)
RAK3153
8,600/7,100
2,550/2,090
11.6/10.6
15
RAK3203
11,700/9,600
3,450/2,820
15.5/14.1
20
RAK3303
17,000/13,900
5,000/4,090
22.3/20.3
30
230/208 Volt Sub-Base Connected Units
Sub-Base
Electric Heat 
(Btuh)
Electric  
Heater Watts
Electric  
Heat Amps
Min. Circuit 
Protection 
(Amps)
RAK204D15P
8,600/7,100
2,550/2,090
11.6/10.6
15
RAK204D20P
11,700/9,600
3,450/2,820
15.5/14.1
20
RAK204D30P
17,000/13,900
5,000/4,090
22.3/20.3
30