York R-410A ZH/ZJ/ZR Series Benutzerhandbuch

Seite von 206
528150-YTG-G-1210
42
Johnson Controls Unitary Products
115°F
125°F
1625
77
78.3
7.0
31.2
26.7
19.5
-
-
-
69.4
7.5
24.9
23.7
17.5
-
-
-
72
70.7
6.8
44.7
37.4
30.1
22.9
-
-
63.1
7.3
40.9
34.3
27.8
21.3
-
-
67
63.2
6.7
58.1
48.0
40.8
33.5
26.2
-
56.8
7.1
56.8
44.7
38.1
31.6
25.1
-
62
55.8
6.5
55.8
55.8
51.1
43.9
36.6
29.3
48.6
6.9
48.6
48.6
48.6
41.9
35.4
28.9
1950
77
80.3
7.0
37.9
29.7
21.4
-
-
-
71.3
7.6
36.4
27.6
19.3
-
-
-
72
72.5
6.9
49.6
41.4
33.2
24.9
-
-
64.8
7.4
47.3
39.0
30.7
22.3
-
-
67
64.7
6.7
61.4
53.1
44.9
36.7
28.5
-
58.3
7.2
58.3
50.4
42.1
33.7
25.4
-
62
57.2
6.6
57.2
57.2
56.3
48.1
39.9
31.6
49.9
6.9
49.9
49.9
49.9
45.1
36.8
28.5
57
61.4
6.6
61.4
61.3
53.1
44.9
36.7
28.4
55.7
7.1
55.7
55.7
48.0
39.7
31.4
23.1
2275
77
82.2
7.1
44.6
32.6
23.4
-
-
-
73.1
7.6
47.8
31.5
21.1
-
-
-
72
74.2
6.9
54.6
45.4
36.2
27.0
-
-
66.4
7.4
53.8
43.6
33.5
23.4
-
-
67
66.3
6.8
64.6
58.2
49.1
39.9
30.7
-
59.7
7.3
59.7
56.1
46.0
35.9
25.7
-
62
58.6
6.6
58.6
58.6
61.5
52.3
43.1
34.0
51.2
7.0
51.2
51.2
51.2
48.3
38.2
28.0
57
62.9
6.7
62.9
62.9
58.0
48.8
39.6
30.5
57.1
7.1
57.1
57.1
52.5
42.4
32.3
22.1
2600
77
84.1
7.1
51.3
35.5
25.4
-
-
-
74.9
7.7
59.3
35.4
22.9
-
-
-
72
76.0
7.0
59.6
49.4
39.3
29.1
-
-
68.1
7.5
60.2
48.3
36.4
24.5
-
-
67
67.9
6.8
67.9
63.3
53.2
43.1
32.9
-
61.2
7.3
61.2
61.2
49.9
38.0
26.0
-
62
60.0
6.6
60.0
60.0
66.7
56.6
46.4
36.3
52.4
7.1
52.4
52.4
52.4
51.5
39.6
27.6
57
64.4
6.7
64.4
64.4
62.9
52.8
42.6
32.5
58.5
7.2
58.5
58.5
57.0
45.1
33.1
21.2
2925
72
77.4
7.0
64.4
53.3
42.1
31.0
-
-
68.5
7.5
63.2
51.2
39.2
27.2
-
-
67
69.1
6.8
69.1
66.8
57.0
45.9
34.8
-
61.6
7.3
61.6
61.6
53.7
41.7
29.7
-
62
61.1
6.7
61.1
61.1
64.4
53.3
42.2
31.0
52.7
7.1
52.7
52.7
52.7
46.2
34.2
22.1
57
65.6
6.7
65.6
65.6
64.8
53.7
42.5
31.4
58.9
7.2
58.9
58.9
58.2
46.1
34.1
22.1
3250
72
78.8
7.0
69.2
57.1
45.0
32.9
-
-
68.9
7.6
66.2
54.1
42.0
29.9
-
-
67
70.3
6.9
70.3
70.3
60.9
48.8
36.6
-
62.0
7.4
62.0
62.0
57.6
45.5
33.3
-
62
62.2
6.7
62.2
62.2
62.2
50.0
37.9
25.8
53.0
7.1
53.0
53.0
53.0
40.9
28.8
16.7
57
66.7
6.8
66.7
66.7
66.7
54.6
42.5
30.3
59.3
7.2
59.3
59.3
59.3
47.2
35.1
23.0
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower 
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZH078 (6.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65