Beko BK 6300 Benutzerhandbuch

Seite von 36
29
Check after installation
Test operation
Ɣ&KHFNDFFRUGLQJWRWKHIROORZLQJUHTXLUHPHQWDIWHU¿QLVKLQJLQVWDOODWLRQ
Items to be checked
Possible malfunction
+DVWKHXQLWEHHQLQVWDOOHG¿UPO\"
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage 
test?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
,VKHDWLQVXODWLRQRISLSHOLQHVXI¿FLHQW"
It may cause condensation and water 
dripping.
Is water drained well?
It may cause condensation and water 
dripping.
Is the voltage of power supply accord-
ing to the voltage marked on the
nameplate?
It may cause malfunction or damaging 
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging 
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci-
¿FDWLRQ"
It may cause malfunction or damaging 
the parts.
Is there any obstruction in the air inlet 
and outlet?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
The dust and sundries caused during 
installation are removed?
It may cause malfunction or damaging 
the parts.
The gas valve and liquid valve of 
connection pipe are open completely?
,WPD\FDXVHLQVXI¿FLHQWFRROLQJ
(heating) capacity.
1. Preparation of test operation
Ɣ7KHFOLHQWDSSURYHVWKHDLUFRQGLWLRQHU
Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW
2. Method of test operation
Ɣ3XWWKURXJKWKHSRZHUSUHVV212))EXWWRQRQWKHUHPRWHFRQWUROOHUWRVWDUW
       operation.
Ɣ3UHVV02'(EXWWRQWRVHOHFW$872&22/'5<)$1DQG+($7WRFKHFN
       whether the operation is normal or not.
Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQć WKHDLUFRQGLWLRQHUFDQ¶W
       start cooling.