3. USEFUL INFORMATION 
AND TROUBLESHOOTING 
PL007D 
PL055D 
PL012D 
E
CONOMY
/
COMFORT  MODE 
The selector knob “E” allows the user to choose the economy mode (position “E”) or the
comfort mode (position “C”).
The economy mode is the normal state for the operation of the boiler, since the domestic
water is heated up only when a tap is turned on.
The comfort mode is a special operating state, because the water contained in the
secondary exchanger and in the primary exchanger is kept in a pre-heated condition,
thereby allowing a quicker delivery of Domestic Hot Water when required.
T
URNING  OFF THE  CENTRAL  HEATING 
To turn off the Central Heating, rotate the “C” knob to the “ 
” position. 
The boiler will stay in ‘summer’ mode, providing Domestic Hot Water on request. 
T
URNING  OFF THE  BOILER 
To turn the boiler off, rotate the selector knob “A” to the “0” position (OFF); the display 
will go off. Close the gas cock located under the boiler and turn the electricity supply 
switch (located outside the boiler) to the OFF position. 
B
OILER  SHUTDOWN  SITUATIONS 
The boiler is equipped with safety devices that intervene in certain situations and shut it 
off. Most of these situations are signalled by means of the L.E.D.s and in some 
circumstances the user may be able to remedy them. 
S
HUTDOWN 
D
UE TO 
I
GNITION 
F
AILURE 
This anomaly is indicated by 
A 01
” on the display. To reset the boiler, press and then
release button “D”.
At this point, the electronic ignition system will attempt to light the burner again.
Should the boiler fail to ignite a second time, check that the external gas cock is 
open. If the problem persists, contact an Authorised Service Centre. 
S
HUTDOWN 
D
UE TO 
O
VERHEATING 
This anomaly is indicated by 
A 03
” on the display. The boiler has shutdown because 
the safety thermostat detected that the boiler temperature has exceeded the maximum 
limit. 
To reset, wait until the boiler has cooled and press button “D”
If the safety thermostat operates on a frequent basis, contact one of our Authorised 
Service Centres. 
S
HUTDOWN 
D
UE TO 
I
NSUFFICIENT 
W
ATER 
C
IRCULATION 
This anomaly is indicated by 
E 02
” on the display. 
One of the possible causes of this shutdown situation could be the lack of water in the 
boiler or water circulation failure in the primary heating circuit. 
Check the system pressure on the pressure gauge “K” and, if it 
is less than 0.5 bar, try bringing the system pressure up to a 
mean value of 1.0 bar by opening the water inlet valve as 
instructed on page 3. Then reset by pressing button “D”. 
O
THER 
S
HUTDOWN 
S
ITUATIONS 
Should a shutdown situation indicated on the display by the following letters and figures 
occur, E04, E05, E06, E07, E08, E09, E20, E33, E34 contact one of our Authorised 
Service Centres.