Crown Boiler ODV-125 Benutzerhandbuch

Seite von 32
2
II Specifications
 
 
Ratings based on #2 fuel oil having a higher heating value of 140,000 BTU/Gal
 
Net ratings based on a piping and pickup loss allowance of 1.15
 
 
Exhaust pipe: 4” I.D. insulated flexible vent pipe.
 
Maximum exhaust pipe length – 15 ft. 
 
Inlet pipe: 4” I.D. Corrugated Aluminum
 
Maximum Inlet pipe length – 20 ft 
 
Maximum Wall Thickness in which Terminal is Installed –  12” 
D.O.E.
HEATING  IBR NET
FIG. 1
NO.
INPUT
CAPY.
RATING
DIMENSION 
MODEL SECTIONS Gal/hr)
(BTU/hr) (BTU/hr) AFUE (%)
"A" (IN.)
ODV-75
3
0.75
91,000
79,000
85.0
32-1/4
24
14
ODV-100
3
1.00
119,000 103,000
83.1
32-1/4
24
14
ODV-125
4
1.25
150,000 130,000
83.5
37-1/4
24
14
FIG. 1 DIMENSION "B" (IN.)
STANDARD
CONNECTION
USING
OPTIONAL
TEE