Lopi 028-S-75-2 Benutzerhandbuch

Seite von 40
14
Stove Installation 
(for qualified installers only)
© Travis Industries
100-01177
4060802
Alcove Installation Requirements
Whenever the stove is placed in a location where the ceiling height is less than 8' tall, it is considered an
alcove installation.  Because of the reduced height, the special installation requirements listed below must
be met.
 
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC connector with AMERI-TEC UL 103 HT chimney
DURAVENT model DVL connector with DURAVENT UL 103 HT chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel HP connector with I.C.C. UL 103 HT chimney
METALFAB model DW connector with METALFAB UL 103 HT chimney
OLIVER MACLEOD PROVENT model PV connector with OLIVER MACLEOD UL 103 HT chimney
SECURITY model DP connector with SECURITY UL 103 HT chimney
SELKIRK model DSP connector with SELKIRK UL 103 HT chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
 
The clearances below must be met:
Minimum Clearance
(See 
Figure 10 below)
Combustible
Alcove
A
Sidewall to stove
18.00"
B
Backwall to stove
20.75"
D
Connector to sidewall
28.25"
E
Connector to backwall
14.00"
G
Maximum depth of alcove
48.00"
H
Minimum width of alcove
63.25"
J
Minimum height of alcove
84.00"
a
d
e
h
j
g
b
Figure 10