ALTERNATE  FLOOR  PROTECTION
All  floor  protection  materials  must  be  non-combustible  ie.  metal,
brick,  stone,  mineral  fiber  boards).    Any  combustible  material
may not be used.
The  easiest  means  of  determining  if  a  proposed  alternate  floor
material  meets  requirements  listed  in  this  manual  is  to  follow  this
procedure.
R-value  =  thermal  resistance
k-value  =  thermal  conductivity
C-value  =  thermal  conductance
1.    Convert  the  specification  to  R-value;
a.  If  R-value  is  given,  no  conversion  is
needed.
b. If k-value is given with a required
thickness  (T)  in  inches:  R=1/k  X T.
c. If C-value is given: R=1/C.
2.    Determine  the  R-value  of  the  proposed  alternate
          floor  protector.
a.  Use  the  formula  in  Step  1  to  convert
values  not  expressed  as  “R”.
b. For multiple layers, add R-values of each
layer  to  determine  overall  R-value.
3.    If  the  overall  R-value  of  the  sustem  is  greater
          than  the  R-value  of  the  specified  floor  protector,
     the alternate is acceptable.
EXAMPLE:
The  specified  floor  protector  should  be  3/4”  thick  material  with  a
k-factor  of  0.84.    The  proposed  alternate  is  4”  brick  with  a  C-
factor  of  1.25  over
1/8”  mineral  board  witha  k-factor  of  0.29.
Step  A.    Use  formula  above  to  convert  specifications  to  R-value.
R=1/k X T= 1/.84 X .75 = .893
Step B.  Calculate R of proposed system.
4”  brick  of  C-1.25,  therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8”  mineral  board  of  k  =  0.29  therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8  +  0.431=1.231
Step C.  Compare proposed system R = 1.231 to specified R of
0.893.    Since  R  is  greater than required,  the  system  is  acceptable.
Definitions:
Thermal  conductance  =
C =        Btu        =           W
                      (hr)(ft
2
)(F)          (m
2
)(K)
Thermal  conductivity  =
            
k =
     Btu        =           W        =     (Btu)
                  (hr)(ft
2
)(F)          (m
2
)(K)       (hr)(ft)(F)
Thermal  resistance  =
R = 
     Btu        =       (m
2
)(K)      =     (Btu)(inch)
                     (hr)(ft
2
)(F)               W                  (hr)(ft
2
)(F)
FOR THE JØTUL F 3 CB  WOOD STOVE REQUIRES
FLOOR  PROTECTION  WITH A  MINIMUM  INSULATING
 R VALUE OF 1.1.
ALCOVE INSTALLATION REQUIRE A MINIMUM R VALUE
OF 1.1. (IF A UL/ULC or WHI LISTED HEARTH PAD IS NOT
USED.)
APPENDIX A:
20
F 3 CB PARTS LIST
2
Inner rear heatshield
2B
Outer rear heatshield
6
Smoke outlet cover
7
Traverse bar
8
Top plate with smoke cover
11
Baffle plate
12
Air distributor
15
Back plate
22
Side plate
23
Back burn plate
24
Right burn plate
26
Air deflector
28
Sliding air vent
29
Front plate
31
Log retainer
35
Door
37
Hinge pin
40
Start-up air vent
42
Door handle complete
43
Locking bar
45
Glass
46
Sparkscreen
51
Ashlip
52
Leg
55
Bottom plate
57
Inner bottom plate
59
Left burn plate
62
Secondary air cover
64
Flat ash housing gasket
65
Ash housing
70
Ashpan
76
Ashpan door
73
Stove tool
78
Door latch
79
Bottom heatshield
ONLY USE REPLACEMENTS PARTS
PROVIDED THROUGH YOUR
  AUTHORIZED  JØTUL  DEALER.