Sony MKE-8020A Benutzerhandbuch

Seite von 34
2-1
MVE-8000A
Flow2
The monitor picture is not displayed correctly even
though the main power of the MVE-8000A is turned on.
Are the plug-in boards inserted into their correct slots?
Are the option boards inserted into their correct slots?
Are the input and output cables connected correctly?
Insert the plug-in boards into the correct slots.
(Refer to the MVE-8000A-C Maintenance Manual.)
Insert the option boards into the correct slots 
respectively. (Refer to Section 1-4.) 
YES
NO
NO
Connect the input and output cables and equipment
correctly.
Install the software correctly.
(Refer to the User s Guide.)
NO
NO
Start up the system in the Factory Set mode and
check to see.
NO
YES
YES
Is the software installed correctly?
YES
Is the system set in the Factory Set mode?
YES
The MVE-8000A is probably defective.
YES
*
 About the Factory Set, refer to Chapter  Engineering Setup  
   of the MVS-8000 System User s Guide.
Flow1
The main power of the MVE-8000A cannot be turned on.
(Indicator does not light green.)
Is the POWER switch A of the MVE-8000A turned ON?
Is the power cord of the MVE-8000A connected correctly?
The power supply unit is probably defective.
Set it to ON.
Connect it correctly.
YES
NO
NO
YES
YES
2-1. Troubleshooting
The main power cannot be turned on. (Indicator does not light green.)
The monitor picture is not displayed correctly.
Section 2
Service Overview