Cisco DWDM SFP DWDM-SFP-5332= Datenbogen

Produktcode
DWDM-SFP-5332=
Seite von 5
 
 
Data Sheet 
All contents are Copyright © 1992–2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 2 of 5 
Connectors and Cabling 
 
Equipment: standard SFP interface network: dual LC/PC connector 
Note:  
  Only connections with patch cords with PC or UPC connectors are supported. Patch 
cords with APC connectors are not supported. 
All cables and cable assemblies used must be compliant with the standards specified in the 
standards section. 
Environmental Conditions and Power Requirements 
 
Operating temperature range: 32 to 158°F (0 to 70°C ) 
 
Storage temperature range: –40 to 185°F (–40 to 85° C) 
Dimensions 
 
Dimensions (H x W x D): 8.5 x 13.4 x 56.5 mm 
 
Cisco SFPs typically weigh less than 75 grams. 
 
Table 1 describes the electrical power interface details, and Table 2 describes optical parameters. 
Table 1. 
Electrical Power Interface Data  
Parameter 
Symbol 
Minimum 
Typical 
Maximum 
Units 
Supply Current 
I
s
 
– 
200 
300 
mA 
Surge Current 
I
Surge
 
– 
– 
30 
mA 
Input Voltage 
V
cc
 
3.1 
3.3 
3.5 
Table 2. 
Optical Parameters 
Parameter 
Symbol 
Minimum 
Typical 
Maximum 
Units 
Notes and Conditions 
Transmitter 
Spectral Width 
 
 
 
0.2 
nm 
Full width, –20dB 
from maximum, with 
resolution bandwidth 
(RBW) = 0.01 nm 
Transmitter 
Center 
Wavelength 
 
x – 100 
x + 100 
pm 
Refer to Table 4 for 
center wavelengths 
Side-Mode 
Suppression 
Ratio 
SMSR 
30 
 
 
dB 
 
Transmitter 
Extinction 
Ratio 
OMI 
8.2 
 
 
dB 
 
Transmitter 
Optical Output 
Power 
P
out
 
 
4.0 
dBm 
Average power coupled 
into single-mode fiber 
Receiver 
Receiver 
Optical Input 
Wavelength 
 
1530 
 
1565 
nm 
 
Receiver 
Damage 
Threshold 
 
 
 
+5 
dBm 
 
Power-Limited Performance at OSNR of 20 dB (1 GbE or 1-Gbps FC) or 21 dB (2 Gbps FC) at 0.1-nm RBW 
Optical Input 
Power 
P
in
 
–28.0 
 
–9.0 
dBm