Lightolier SL111B1 Benutzerhandbuch

Seite von 5
KUBIK 1.5 
SL111B1
Page 4 of 5 
Louver Stand-Off Unit
Lightolier 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2008 Philips Group • SL111B1.pdf
SL003J
Job Information 
Type:
Canlyte 
www.canlyte.com
3015 Louis-Amos, Lachine, Québec  H8T 1C4 • (514) 636-0670 • (514) 636-0460
 
 
  
ZONE  
 
 
 
 
 
DEG   
 
ALONG  22.5 
45 
67.5 
ACROSS
 
 
 
 
 
 
    0 
326 
326 
326 
326 
326
    5 
339 
330 
331 
331 
322
  15 
323 
325 
335 
341 
339
  25 
300 
309 
331 
347 
345
  35 
261 
285 
318 
337 
343
  45 
215 
251 
296 
320 
329
  55 
162 
209 
262 
302 
318
  65 
111 
165 
234 
289 
308
  75 
59 
125 
217 
279 
303
  85 
22 
96 
198 
268 
292
  90 
15 
88 
191 
251 
270
  95 
16 
94 
197 
269 
295
105 
15 
115 
206 
269 
294
115 
13 
147 
220 
275 
295
125 
16 
136 
238 
281 
294
135 
16 
95 
247 
281 
296
145 
17 
44 
165 
256 
277
155 
13 
14 
78 
146 
164
165 
16 
14 
11 
28 
41
175 
16 
15 
1
180 
 9 
9
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
  
 
     80  
  
               70   
  
 
50
Wall Reflectance
 
70  50  30  10  70  50 
30  10  50  30 
10
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
LUMINAIRE INPUT WATTS = 26.4
Room Cavity Ratio
ZONE 
LUMENS 
% LAMP 
% LUMINAIRE
0-30 
277 
10.62 
10.63
0-40 
471 
18.07 
18.08
0-60 
918 
35.18 
35.20
0-90 
1548 
59.33 
59.36
40-90 
1076 
41.25 
41.28
60-90 
630 
24.15 
24.16
90-180 
1060 
40.62 
40.64
0-180 
2608 
99.95 
100.00
DISTRIBUTION
CANDLEPOwER CURVE
Performance
CANDLEPOwER
RePoRT No: C9932
CAT. NO: SL111B128PI
1 x 28W T5 at 2610 Lumens
efficiency: 99.9 % 
Candela at Nadir: 326cd
0
°
90
°
90
°
180
°
200
400
600       
 
  0  1.09  1.09  1.09  1.09  1.02  1.02  1.02  1.02  .88  .88  .88
  1  .97  .91  .86  .82  .90  .85  .81  .76  .73  .70  .67
  2  .87  .78  .71  .64  .81  .73  .66  .60  .62  .57  .53
  3  .79  .68  .59  .53  .73  .63  .56  .50  .55  .49  .44
  4  .72  .60  .51  .44  .66  .56  .48  .41  .48  .41  .36
  5  .65  .52  .43  .36  .60  .49  .41  .34  .42  .35  .30
  6  .60  .47  .38  .31  .55  .43  .35  .29  .37  .31  .26
  7  .55  .42  .33  .27  .51  .39  .31  .25  .34  .27  .22
  8  .51  .37  .29  .23  .47  .35  .27  .22  .30  .24  .19
  9  .47  .34  .25  .20  .43  .31  .24  .19  .27  .21  .17
 10  .43  .31  .23  .17  .40  .28  .21  .16  .25  .19  .15
Options and Accessories
Emergency Lighting: Electronic Bodine slim profile battery pack. The emergency 
ballast senses the power failure and immediately switches to emergency made 
by illuminating the lamp at a reduced lumen output for a minimum of 90 mins. The 
battery fully recharges within 24 hours. Add suffix (EM) to the catalogue numbers.
DALI Interface: Digital Addressable Lighting Interface available upon request  
for individual luminaires. Ballast 120 volts or 277 volts only. Consult your  
Lightolier representative.
Markings
cULus Listed Suitable for damp locations.
Mounting
Direct Mount: Square canopies or invisible feed suitable for plaster ceiling, exposed 
ceiling or suspended ceilings mounts.
Suspended Mount: Single stem or aircraft cable with round canopy suitable  
for mounting on a standard outlet box for plaster ceiling exposed installation  
or suspended ceilings mounts. Stem and cable mounts can both be used on the  
same luminaire.
Patterns: Suitable for different patterns in continuous row mounting.
Electrical
Ballast: Electronic slim profile 1 lamp 28W T5 or 54W T5H0 Iinear ballast.
U: Universal voltage ballast automatically detects 120V to 277V, 50 or 60Hz 
operations.
1: 120V ballast only.
2: 277V ballast only.
H: 347V ballast only.
Lampholder: G5 plug-in base, miniature Bi-pin.
Finish
Natural brushed and anodized aluminum. All painted parts are powder coat  
paint process.
Lightolier is a Philips group brand