Cooper Lighting P2E-VM Merkblatt

Seite von 1
COOPER LIGHTING - LUMARK
®
INDUSTRIAL
521
COOPER LIGHTING
D I M E N S I O N S
• Standard quick mounting
plate for 3/4" IPS conduit
frees both hands to 
complete wiring
• Die-cast aluminum 
housing has durable white
polyester powder coat 
finish
• Hinged refractor permits
relamping without
removal of refractor
• Acrylic prismatic refractor
controls light for high 
vertical and horizontal
footcandles
• Removable ballast 
compartment cover 
provides easy internal
access
• Optional “P” mounting 
bracket fits a standard 
4" J-Box or outlet box 
for surface mounting
• Approximate net weight: 
7 lbs. (8 kgs.)
D E S C R I P T I O N
The Vertimark II delivers 
horizontal and vertical 
footcandles to evenly illuminate
low mounting areas such 
parking garages or storage
facilities areas. 
The combination die-cast
reflector/ ballast housing 
makes Vertimark II economical.
Modular assembly makes
installation easy and quality
construction ensures years of
consistent performance. U.L.
listed and labeled for damp
location. CSA Certified. Wet
location optional.
BE
VERTIMARK II
1 0 0 - 2 5 0 W
H i g h   P r e s s u r e   S o d i u m
P u l s e   S t a r t   M e t a l   H a l i d e
M e t a l   H a l i d e
L O W - B AY
I N D U S T R I A L   L U M I N A I R E
NOTES: 1 150W is maximum wattage available in HPS. Pulse Start Metal Halide available on 100, 150, 175, 200, and 250W only. 250W only. MD available in 208,
240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. Not recommended for use with Metal Halide lamps due to to rapid 
yellowing typical of polycarbonate material. For 120V NPF Reactor ballast, drop “H” after wattage in catalog number. Products also available in non-US 
voltages and 50Hz for international markets. Consult factory for availability and ordering information. 480V not available with 200 or 250W Pulse Start Metal
Halide. Multi-Tap ballast is 120/208/240/277V wired 277V. 10 Triple-Tap ballast is 120/277/347V wired 347V. 11 Add as suffix in the order shown. 
12 Specifications and dimensions subject to change without notice.
O R D E R I N G   I N F O R M A T I O N
S A M P L E   N U M B E R :   H P B E - 5 A - 1 0 0 H - M T- L L
Lamp Type
HP
=High
Pressure
Sodium
1
MH=Metal 
Halide
MP=Pulse
Start MH (CWA)
2
MD=Pulse Start Metal Halide (Electronic)
3, 4
Series
BE
=Vertimark II
Lens Type
2A
=Type II
5A=Type V
2P=Type II
Polycarbonate
5
5P=Type V
Polycarbonate
5
Lamp Wattage
100
=100W
150=150W
175=175W
200=200W
250=250W
Power Factor
H
=HPF
=NPF
6
Voltage 
7
120V
208V
4
240V
4
277V
4
347V
480V
8
MT=Multi-Tap
9
TT=Triple-Tap
10
E=Electronic
4
LL=Lamp
Included
Options &
Accessories
11
(See Pages 
541-545)
Once in place, the EZ123
readily accepts the 
mating half of the hinge
and the fixture is 
easily attached.
2 9/16"
[65mm]
5 1/8"
[130mm]
P=Mounting Bracket for 
Surface Mounting or 
Mounting to 4" J-Box.
17" [432mm]
Surface
12 1/2"
[318mm]
Pendant
13 1/4"
[337mm]
P o w e r e d   b y
t e c h n o l o g y
M O U N T I N G
% Lamp Sur
vival 
LAMP MORTALITY 
2000 4000 6000 
10000 
8000 
12000 14000 16000 18000 20000 22000 24000 26000 28000 30000 
0
90
80
70
60
50
40
30
20
10
0
100
Lamp Life [Hours] 
Natural White   & Uni-Form   Pulse Start on ECON TECHNOLOGY                  Uni-Form   Pulse Start on CWA                  Probe Start Metal Halide on CWA 
TM ® 
®
% Lumens 
LUMEN MAINTENANCE 
2000 4000 6000 
10000 
8000 12000 
14000 
16000 
18000 
20000 
40
90
80
60
70
50
0
90% Mean Lumens Nat-Wt-ECON             86% Mean Lumens-UPS-ECON             75% Mean Lumens-UPS CWA 
65% Mean Lumens-Probe Start 
100
Lamp Life [Hours] 
L A M P   M O R T A L I T Y   A N D   L U M E N   M A I N T E N A N C E   C O M P A R I S O N S
NOTE: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE
®
Lamp
Series
Wattage
90°C
40°C (100-250W)
40°C (250W ECON)*
Supply
Wire (Min.)
Ambient
Environment
Vertimark II
100-250W
NOTES: * Electronic Pulse Start Metal Halide. (200-277V). 120V 25°C.